SD750FR
Parámetro
Pantalla
Timeout máximo parada =
G11.2.1
Desactivado
G11.2.2
I fuga tierra máxima = 20% In
G11.2.3
Ret fallo dsq I sal = 5.0s
G11.2.4
Retardo fallo dsq VS = 5.0s
Fallo
PT100
G11.2.5
Desactivado
G11.2.6
Fallo PT100 timeout = 30s
G11.2.7
Fallo sin carga = No
Nivel sobrecarga bomba =
G11.2.8
20.0A
Filt sobrecarga bomba =
G11.2.9
Desactivado
G11.2.10
Ret sobrecarga bomba = 60
G11.2.11
Activar subcarga bomba = No
Nivel subcarga bomba =
G11.2.12
1.0In A
G11.2.13
Vel subcarga bomba = 100.0%
G11.2.14
Ret subcarga bomba = 10.0s
PMSM Umbral Desinc. =
G11.2.15
40.0 %
PMSM Tiempo Desinc. =
G11.2.16
0.10 s
G12.1
Activar autoreset = No
G12.2
Núm máx intentos = 1
G12.3
Retardo autoreset = 5 s
G12.4
Tiempo reset contador = 15min
G12.5
Fallo 1 autoreset =
G12.6
Fallo 2 autoreset =
G12.7
Fallo 3 autoreset =
G12.8
Fallo 4 autoreset =
G13.1
Registro fallo 1 = 0
G13.1b
Fecha = 01/01/2000 00:00
G13.2
Registro fallo 2 = 0
G13.2b
Fecha = 01/01/2000 00:00
G13.3
Registro fallo 3 = 0
G13.3b
Fecha = 01/01/2000 00:00
G13.4
Registro fallo 4 = 0
G13.4b
Fecha = 01/01/2000 00:00
G13.5
Registro fallo 5 = 0
G13.5b
Fecha = 01/01/2000 00:00
G13.6
Registro fallo 6 = 0
G13.6b
Fecha = 01/01/2000 00:00
G13.7
Borrar historial = No
G14.1
Multi-referencias 1 = 10.00%
G14.2
Multi-referencias 2 = 20.00%
G14.3
Multi-referencias 3 = 30.00%
G14.4
Multi-referencias 4 = 40.00%
100
COMUNICACIÓN MODBUS
Dirección
Desactivado = 0
40432
Desactivado = 0
40433
40451
Desactivado = 10.1
40438
Desactivado = 10.1
motor
=
Desactivado = -21
40440
40459
40454
40441
Desactivado = 0
40442
Desactivado = 0
40443
40444
40445
40446
40447
40457
40458
Desactivado = 5.01
40461
40462
40463
40464
40465
Desactivado
40466
Desactivado
40467
Desactivado
40468
Desactivado
40481
01/01/2000 00:00 a
41531
31/12/2127 23:59
40482
01/01/2000 00:00 a
41533
31/12/2127 23:59
40483
01/01/2000 00:00 a
41535
31/12/2127 23:59
40484
01/01/2000 00:00 a
41537
31/12/2127 23:59
40485
01/01/2000 00:00 a
41539
31/12/2127 23:59
40486
01/01/2000 00:00 a
41541
31/12/2127 23:59
40487
40501
-250.00 a 250.00%
40502
-250.00 a 250.00%
40503
-250.00 a 250.00%
40504
-250.00 a 250.00%
Rango
Rango Modbus
0 a 9990
0.1 a 999s
0 a 3000
0 a 30% In
0.0 a 10.0s,
0 a 101
0.0 a 10.0s,
0 a 101
69 a 180
-20 a 180ºC
0 a 3000s
0 a 3000
No
Sí
0.0 a 3000 A
0 a 30000
0 a 200
0.1 a 20.0s
0 a 4800
1 a 480.0s
No
Sí
0.2In a 1.5In
2000 a 15000
0.0 a 250.0%
0 a 25000
0.0 a 999.9 s
0 a 9999
0.0 a 100.0 %
0 a 10000
0.00 a 5.00s
1 a 501
No
Sí
1 a 5
1 a 5
5 a 120s
5 a 120
1 a 60min
1 a 60
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 1024
0 a 1024
0 a 65535
0 a 1024
0 a 1024
0 a 65535
0 a 1024
0 a 1024
0 a 65535
0 a 1024
0 a 1024
0 a 65535
0 a 1024
0 a 1024
0 a 65535
0 a 1024
0 a 1024
0 a 65535
No
Sí
-25000 a 25000
-25000 a 25000
-25000 a 25000
-25000 a 25000
POWER ELECTRONICS
Acceso
[1]
RW
RW
RW
RW
RW
RW
0
RW
1
RW
RW
RW
0
RW
1
RW
RW
RW
RW
RW
0
RW
1
RW
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
0
RW
1
RW
RW
RW
RW