Preventive Maintenance; Brush Removal; Brush Replacement; Filter Replacement - Wyco Sure Speed WVD1 Manual Del Operador Y De Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18

PreveNtIve mAINteNANce

Wyco vibrator motors are designed to operate 50
to 100 hours between normal "preventive main-
tenance" intervals. The service instructions below
should be followed to perform the preventive
maintenance.
nOTE: There are no user serviceable parts
contained within the motor housing. Open-
ing the motor housing may be dangerous
and will void the warranty. Any repairs that
require opening the motor housing should
WARNING
be performed at an authorized Wyco service
center or at the Wyco factory. use only factory authorized
replacements parts.

brush removal

For the location of the parts used in the following
procedures refer to Figure 3.0.
1. Disconnect the line cord from power source.
2. Lay the motor on its side with brush cap (6)
facing upwards.
3. Use a 3/8 inch (6-sided) socket to unscrew the
plastic brush cap (6) from the motor half.
4. The brush spring (5) will pop out. Carefully re-
move the brush spring by gently pulling on the
spring.
5. Repeat steps for the opposite side.
Form No. W160 02/10

brush replacement

nOTE: Brushes should be replaced in pairs.
1. Align new brush (5) with brush holder and
insert.
2. Push the spring into the holder as the brush cap
is screwed back into the housing.
nOTE: The O-ring must be on the brush cap before screwing
into the housing.
3. Repeat steps for opposite side.

Filter replacement

1. Pull the old filter down from the housing with
your fingers.
2. Place the new filter (2) in the housing, tapered
side up. (See Figure 3.0.)