90503223 FS360 screwdriver
6. Make sure cord is located so that it will not be stepped on, tripped over, or otherwise
subjected to damage or stress.
7. An extension cord should not be used unless absolutely necessary. Use of improper
extension cord could result in a risk of fire, electric shock or electrocution.
a) Two-wire cords can be used with 2-wire or 3-wire extension cords. Only round jacketed
extension cords should be used, and we recommend that they be listed by
Underwriters Laboratories (U.L.). If the extension is to be used outside, the cord must
be suitable for
outdoor use. Any cord marked for outdoor use can also be used for indoor work. The
letters "W" or "WA" on the cord jacket indicate that the cord is suitable for outdoor use.
b) An extension cord must have adequate wire size (AWG or American Wire Gauge) for
safety, and to prevent loss of power and overheating. The smaller the gauge number of
the wire, the greater the capacity of the cable; that is, 16 gauge has more capacity than
18 gauge. When using more than one extension to make up the total length, be sure
each extension contains at least the minimum wire size.
8. Use only the supplied charger when charging your tool. The use of any other charger
could damage the tool or create a hazardous condition.
9. Use only one charger when charging.
10. Do not attempt to open the charger. There are no customer serviceable parts inside.
Return to any authorized Black & Decker service center.
11. DO NOT incinerate the tool or batteries even if they are severely damaged or
completely worn out. The batteries can explode in a fire.
12. A small leakage of liquid from the battery cells may occur under extreme usage,
charging or temperature conditions. This does not indicate a failure. However, if the
outer seal is broken and this leakage gets on your skin:
a. Wash quickly with soap and water.
b. Neutralize with a mild acid such as lemon juice or vinegar.
c. If the battery liquid gets in your eyes, flush them with clean water for a minimum of 10
minutes and seek immediate medical attention. MEDICAL NOTE: The liquid is a 25-35%
solution of potassium hydroxide.
Charging Procedure
IMPORTANT: The batteries in your power pack are not fully charged at the factory. Before
attempting to charge them, thoroughly read all of the safety instructions. The 3 hour
charger is designed to use standard household 120 volt 60 Hz power. To charge the
battery, follow the steps below:
1. Put the forward / reverse / lock off slider (2) in the center OFF position, press in on
both release buttons (8) simultaneously and remove battery from the tool.
2. Plug the charger (9) into any standard 120 Volt 60 Hz electrical outlet. (Fig. A)
3. Insert the battery pack (7) into the charger and let it charge for 9 hours. (Fig. A)
4. Unplug the charger and remove battery pack.
5. Insert the battery pack into the grip of the screwdriver until it clicks into place. (Fig. B)

Important Charging Notes

1. After normal usage, your tool should be fully charged in 3 to 6 hours. If the batteries
are run down completely, it may take up to 6 hours to become fully charged. Your tool
was sent from the factory in an uncharged condition. Before attempting to use it, it
must be charged for at least 9 hours.
2. DO NOT charge the batteries in an air temperature below 40°F (4,5 °C) or above
105°F (+40,5 °C). This is important and will prevent serious damage to the batteries.
Longest life and best performance can be obtained if batteries are charged when air
temperature is about 75°F.
3. While charging, the charger may hum and become warm to touch. This is a normal
condition and does not indicate a problem.
4. If the batteries do not charge properly:
(1) Check current at receptacle by plugging in a lamp or other appliance.
(2) Check to see if receptacle is connected to a light switch which turns power off
5/10/06