Description of the Appliance
The scope of delivery of your appliance is illustrated on
the packaging. Check the contents of the appliance for
completeness when unpacking.
In the event of missing accessories or any transport
damage, please contact your dealer.
Illustrations on Page 2
1
Water connection with integrated sieve
2
Coupling element for water connection
3
High pressure connection
4
Accessory compartment
5
Carrying handle
6
Mains cable with mains plug
7
Cable clip
8
Storage for mains cable
9
Appliance switch „0/OFF" / „I/ON"
10 Trigger gun
11 Lock trigger gun
12 Clamp for high pressure hose
13 Safety cover
14 Spray lance extension
15 Spray lance with pressure regulation (Vario Power)
The working pressure can be continuously in-
creased from "SOFT" to "HARD". To adjust the
working pressure, release the trigger gun lever and
turn the spray lance to the desired position.
16 High pressure hose
* Additionally required
17 Fabric-reinforced water hose with commercially
available coupling.
– Minimum diameter, 1/2 inches (13 mm).
– Minimum length 7.5 m.
Assembly
Mount loose parts delivered with appliance prior to start-
up.
Illustrations on Page 3
Illustration
Screw the coupling element to the water connec-
tion on the appliance.
Illustration
Pull out the clamp for the high pressure hose from
the trigger gun.
Illustration
Connect high pressure hose to trigger gun.
Push the clamp in until it locks. Check the secure
connection by pulling on the high-pressure hose.
Park the appliance on an even surface.
Illustration
Connect the high pressure hose to the high pres-
sure connection of the appliance.
Check the secure connection by pulling on the high
pressure hose.
Insert the mains plug into the socket.
For connection values, see type plate/technical data.
Observe regulations of water supplier.
ATTENTION
Impurities in the water can damage the high-pressure
pump and the accessories. For protection, the use of
the KÄRCHER water filter (optional accessory, order
no. 4.730-059) is recommended.
Attach the water supply hose to the coupling on the
water connection.
Connect the water supply hose to the water supply.
Completely open the water tap.
ATTENTION
Dry running of more than 2 minutes leads to damage of
the high-pressure pump. If the appliance does not build
up pressure within 2 minutes, switch the appliance off
and proceed in accordance with the instructions in
Chapter "Troubleshooting".
High pressure operation
CAUTION
Keep a distance of at least 30 cm when using the jet for
cleaning painted surfaces to avoid damage.
Illustration
Push the spray lance extension into the trigger gun
and fasten it by a 90° rotation.
Illustration
Tighten the safety cover.
Illustration
Push the spray lance into the spray lance extension
and fasten it by a 90° rotation.
Turn on the appliance "I/ON".
Unlock the lever on the trigger gun.
Pull on the lever of the trigger gun; the device will
switch on.
Note: Release the lever of the trigger gun; the de-
vice will switch off again. High pressure remains in
the system.
Interrupting operation
Release the lever on the trigger gun.
Lock the lever on the trigger gun.
During longer breaks (more than 5 minutes), also
turn the appliance off using the "0/OFF" switch.
– 5
EN
Start up
Water supply
Operation
9