Commissioning - Cattini Oleopneumatica YAK 300 Manual Uso Y Mantenimiento

Gato oleoneumatico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

EN

COMMISSIONING

ASSEMBLY
1) Extract the handle, the jack and the extensions from the boxes.
2) The handle is divided into three parts. Before use, assemble as per the drawing, using the supplied grub screw and
wrench. DWG. 10
3) The handle is inserted in one of the two seats, in the lower position to position the jack underneath the load or in the
upper position to move it.
CONNECTION TO THE COMPRESSED AIR SYSTEM
- Compressed air enters the jack circuit through the quick coupling located on the jack's manual raising and lowering
control; a connecting hose with a quick coupling compatible with that of the jack is therefore required. Check that the air
supply hose has an internal diameter of at least 6mm, and that there are no kinks or blockages.
Working air pressure: 8 - 10 BAR
- Never allow hydraulic fluid, petroleum jelly, brake fluid, petroleum or other liquids to enter the compressed air circuit.
-Install a drier-lubricator filter unit in the compressed air system.
- If you need to lubricate the compressed air circuit, use only:
AGIP OSO 100; MOBIL DTE 27; ESSO TERESSO 100;
SHELL TELLUS 100; BP ENERGOL HP 100
ACCESSORIES
- The machine is supplied with two extensions or height adaptors (long extension 120mm, short extension 70mm) and a
circular toothed plate (plate 10mm).
Never use more than two extensions!
or injuries resulting from failure to observe the above requirement; this shall also render the warranty
void!
SCRAPPING AND DISPOSAL
- Lubricants must be disposed of in compliance with applicable pollution legislation.
- The user must follow applicable legislation when scrapping the jack and its component parts.
The manufacturer shall not be held responsible for any damage