Iecex Installation Drawing - 5332D - PR electronics 5332 Manual Del Producto

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 5332D the following must be observed. The module shall only be
installed by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
Certificate
Marking
Standards
Hazardous area
Zone 0, 1, 2, 20, 21, 22, M1
T4: -40 ≤ Ta ≤ 85ºC
T5: -40 ≤ Ta ≤ 60ºC
T6: -40 ≤ Ta ≤ 45ºC
Terminal: 3,4,5,6
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4μF
Revision date:
2018-08-22
IECEx Installation drawing
IECEx DEK 13.0035X
Ex ia IIC T4...T6 Ga
Ex ia IIIC Da
Ex ia I Ma
IEC 60079-0 : 2011, IEC 60079-11 : 2011, IEC 60079-26:2006
6
5
4
3
5332D
Terminal: 1,2
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W
Li: 10μH
Ci: 1.0nF
Version Revision
V1R0
5332V101-ES
WWW.PRELECTRONICS.COM
Non Hazardous Area
+
1
-
2
Barrier
5332QI01
0Page:
1/2
13
Tabla de contenido
loading

Tabla de contenido