18.5.3 E4, C0, C1, F7, F8
E4,C0,C1,F7,F8: Malfunction of temperature sensor
Connection ports for temperature sensor on
main PCB are loose or false connected
Temperature sensor is short circuited or disabled (Use a
multi-meter to measure resistance, if the resistance is
too low, the sensor is short circuited, if the resistance in
certain temperature is not consistent with appendix
table, the sensor is disabled)
PCB is damaged
18.5.4 E5
E5: Malfunction of power supply voltage
Voltage of power supply is too high or too low,
the normal voltage between L and N (single
phase), A and N, B and N, C and N (there
phase) should be 198V~252V
PCB is damaged
No
No
Replace PCB
No
Replace PCB
Yes
Fasten or reconnect the
temperature sensor ports
Yes
Replace the sensor
Yes
Provide normal power
supply
V.2