STAGE 1: PRELIMINARY OPERATIONS
• Turn OFF the 115 V mains power (switch)
• LINK LK1 JUMPER
• Turn ON again mains power
• Check if the DL2 indicator light is ON
• Take the remote-control and open the door. Turn it so
that you can read the 12 digits of the DIP SWITCHES.
See the drawing beside
OPEN THE
DOOR
DIP-SWITCHES
from 1 to 12
PUSH-
BUTTON 1
PUSH-
BUTTON 2
T
HE FUNCTIONS ARE ADJUSTED WITH YOUR REMOTE CONTROL
T
4
HE
PROGRAMMING STAGES MUST BE EFFECTED
FUNCTION 1: WORK TIME ADJUSTMENT
(jack stroke + 2 seconds operation on limit stops)
ON
13 seconds
OFF
1 2 3
12
ON
15 seconds
OFF
1 2
3
12
ON
17 seconds
OFF
1 2
3
12
ON
18 seconds
OFF
1 2
3
12
FUNCTION 3: OPERATING MODE
1) Stepped:
Opening must be controlled via remote-control
Closing must be controlled via remote-control
ON
OFF
6
8
7
12
2) Automatic:
Opening must be controlled via remote-control
Closing will be automatic after the chosen pause time:
Pause time to be chosen:
4 seconds
6
7
8
12
8 seconds
ON
OFF
6
7
8
12
17 seconds
recommended
6
7
8
12
25 seconds
6
7
8
12
t s
t a
s u
o
p
e
n
n i
g
c
c
o l
s
e
d
O
p
e
s n
L
o
c
s k
a
n
d
o
p
e
n
n i
g
c
o
m
m
a
n
d
o
p
e
n
l C
s o
s e
L
o
c
s k
a
n
d
c
o l
s
n i
g
c
o
m
m
a
n
d
PROGRAMMING
,
USING THE
STAGE 2: FUNCTION ADJUSTMENT
BEFORE BEGINNING TO PROGRAM:
POSITION DIP No.12
of the remote-control to ON
20 seconds
ON
OFF
1 2
3
12
22 seconds
ON
RECOMMENDED
OFF
1 2
3
12
23 seconds
ON
OFF
1 2
3
12
ON
25 seconds
OFF
1
2
3
12
}
OBLIGATORY IF NOT
PHOTOCELLS PROVIDED
RECOMMENDED MODE
DURING THE ADJUSTMENTS
ON
ON
50 seconds
OFF
OFF
6
7
8
12
ON
ON
100 seconds
OFF
OFF
6
7
8
12
ON
ON
150 seconds
OFF
OFF
6
7
8
12
ON
OFF
S
e t
p
p
e
d
u f
n
t c
o i
n
o l
g
c i
o
m
m
a
n
d
f e
e f
t c
p
h
o
o t
c
e
l l
f e
e f
t c
N
o
f e
e f
t c
l c
s o
s e
o
n
u s
c
c
e
s s
v i
e
N
o
f e
e f
t c
P
e r
v
e
n
s t
l c
s o
n i
g
o
p
e
s n
o
n
u s
c
c
e
s s
v i
e
O
p
e
s n
10
-
12
MICRO DIP
SWITCHES
ON
OFF
12
FUNCTION 2: DELAY ADJUSTMENT DURING LEAF CLOSING
nd
(2
leaf delay)
ON
0 seconds
OFF
4
5
12
1.5 seconds
ON
recommended
OFF
4 5
12
FUNCTION 4: MOTOR POWER ADJUSTMENT
(
)
TORQUE ADJUSTMENT
ON
Max. 100%
OFF
9 10
11
12
ON
OFF
9 10
11
12
ON
OFF
9 10
11
12
ON
OFF
9
10
11
12
Automatic function logics
status
opening command effect
closed
Opens
No effect
opening
on pause
Re-loads pause time
closing
Opens
ON
3 seconds
OFF
4 5
12
ON
7 seconds
OFF
4
5
12
ON
OFF
9 10
11
12
ON
OFF
9 10
11
12
ON
OFF
9 10
11
12
ON
Min. 12%
OFF
9 10
11
12
photocell effect
No effect
No effect
Prevents closing
Opens

Hide quick links: