Troubleshooting
You can rectify minor faults yourself with the help of the
following overview.
If in doubt, please consult the authorized customer ser-
vice.
DANGER
Risk of electric shock.
Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.
Appliance is not running
Pull on the lever of the trigger gun; the device will
switch on.
Check whether the voltage indicated on the type
plate corresponds to the voltage of the mains sup-
ply.
Check the mains connection cable for damages.
Pressure does not build up in the appliance
Appliance ventilation: Switch the appliance on with
the high-pressure hose detached and operate
(max. 2 minutes) until the water exits the high-pres-
sure connection without bubbles. Switch off appli-
ance and reconnect high-pressure hose.
Check the water supply.
Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
Strong pressure fluctuations
Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Appliance is leaking
Slight leakage from the appliance pump is normal.
If the leakage increases contact the authorized
customer service.
No detergent infeed
Detach spray lance from the trigger gun. Work only
with the trigger gun.
Clean the detergent suction hose filter.
Check the detergent suction hose for kinks.
Warranty
The warranty terms published by the relevant sales
company are applicable in each country. We will repair
potential failures of your appliance within the warranty
period free of charge, provided that such failure is
caused by faulty material or defects in manufacturing. In
the event of a warranty claim please contact your dealer
or the nearest authorized Customer Service centre.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch
20 English
Technical specifications
Electrical connection
Voltage
Power consumption
Protection class
Protective class
Mains fuse (slow-blow)
Water connection
Max. feed pressure
Max. feed temperature
Min. feed volume
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Max. flow rate
Detergent flow rate
Recoil force of trigger gun
Dimensions and weights
Length
Width
Height
Weight, ready to operate with ac-
cessories
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
+ Uncertain-
WA
ty K
WA
Subject to technical changes.
220-240
V
1~50-60
Hz
6 A
IP X5
II
10 A
1,2 MPa
40 °C
8 I/min
8 MPa
11 MPa
5,5 I/min
6,0 I/min
0,3 I/min
10 N
448 mm
283 mm
252 mm
5,4 kg
<2,5
m/s
2
0,3
m/s
2
76
dB(A)
2
dB(A)
90 dB(A)