Alemite 3400 Serie Guía De Servicio página 9

Bomba de transferencia de combustible
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SER 3400
Operation
1. Remove the Control Nozzle from the Nozzle
Hanger.
2. Place the outlet of the Control Nozzle into the de-
sired tank.
Do not hold the Fuel Nozzle in the
center of the tank opening while illing.
Always keep the Control Fuel Nozzle
outlet in contact with the tank being
illed. Contact between the Fuel Nozzle and tank being
illed grounds the system.
Failure to maintain contact between tank and nozzle
involves a risk of ire or explosion and may result in
injury.
3. Rotate the Switch Lever to the On (up) position.
4. Engage the Control Nozzle handle to dispense fuel.
Do not rig Fuel Nozzle handle to
stay open.
Do not leave pump unattended while
dispensing fuel.
The Fuel Nozzle is not equipped with an automatic
shut off device when the tank approaches full.
Always watch the tank level closely and disengage
the nozzle so the tank does not overlow. Fuel over-
lows can result in injury such as skin irritations and
burns if it comes in contact with the user.
5. When the tank is full or at the desired level, release
the nozzle handle to close the nozzle valve and stop
dispensing fuel.
Do not operate pump in bypass mode
for more than 30 minutes. Bypass mode
is when the motor is on but the Control
Nozzle is not open and dispensing fuel.
Operating the pump for more than 30 minutes in bypass
mode can cause failure to the motor.
Alemite, LLC
WARNING
WARNING
CAUTION
6. Rotate the Switch Lever to the Off (down) position
to turn off the pump motor.
7. Remove the Fuel Nozzle from the tank and return it
to the Nozzle Hanger.
8. If Alligator Clips are used for power connection
- disconnect the Alligator Clips from the power
source.
Service
Rotor and Vane Replacement
1. Remove the three screws from the cover plate.
2. Remove the cover plate. Note the direction of the
vanes and rotor as shown.
3. Replace any worn or damaged components.
4. The rotor is designed to allow it to only be assem-
bled one way. Do not force the rotor onto the motor
shaft.
5. Align the O-ring and cover plate.
6. Torque the (3) M6-1mm screws to 22 in-lb
(2.5 N-m).
NOTE: Do not over-torque screws. This can result
in damage to the casting and wear of rotor.
9