Flotec EP2-04 Manual Del Usuario página 7

Sistema de bomba de sobrepresión de paletas periféricas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operation
Operation As A Rooftop
Reservoir Booster Pump
1. Open a faucet near the pump.
2. Plug the pump into a GFCI-protected, grounded,
3-wire outlet. The pump should start.
3. Let the pump run until all air is out of the system and
the faucet is running solid water.
4. When the faucet is running solid water, close the
faucet. The pump should run until the water pressure
rises to the pressure switch's OFF setting. The pump
should then stop.
NOTE: Check the system by running it through one
complete pumping cycle to make sure it works. To do
this, open a faucet and bleed off pressure until the
pump starts. Close the faucet, and when the pressure
in the system has built up again, the pump should
stop.
Congratulations on a successful installation.
If you were unsuccessful, please refer to the
Troubleshooting section (Page 8) or call our customer
service technical staff at 1-262-728-5551.
For parts or assistance, call Flotec Customer Service at
Neutral
115V
Booster Pump
Float Switch:
Circuit
Up = On
Breaker
Down = Off
Box
Hot
Pump
Cistern Pump
Float Valve
Cistern
Foot Valve
Float Switch:
Up = On
Down = Off
Wiring Connections – Schematic
Booster Pump
Float Switch
(In Tinaco)
Hot
Cistern Float
Circuit
Switch
Breaker
(In Cistern)
Box
Neutral
Figure 5 – Cistern/Tinaco Booster Application.
1-262-728-5551
Pump-Up
Float Switch:
Up = Off
Down = On
Tinaco
Pressure
Tank
Pump
Pump
Pressure Booster Pump
City Water Inlet
NOTE: If the cistern pump is
connected directly to the city
water line, install a Flow Switch
or Low Pressure Cutoff if city
service may be interrupted.
Pressure
Booster
Pump
Hot – Brown
(In Tinaco)
Cistern
Pump-Up
Pump
Float Switch
Neutral – Black
4581 0404
7
Tabla de contenido
loading

Tabla de contenido