Madas EVQ-1 Manual Del Usuario página 22

Electroválvula automática normalmente cerrada para gas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

8.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described herein;
• Failure to observe the regulations pertaining to installation;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, other manufacturers's assembling units, making changes to the device and
natural wear.
9.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
• CE-51CR4682 (if it is present) = certification pin number
• Cl. A
• Gr. 2
• EN 161
• P. max
= Maximum pressure at which product operation is guaranteed
• PS
= Allowable maximum pressure
• IP....
• 230V....
• Example of electrical absorption indication: 270/70 VA indicates 270 VA at start, 70 VA at steady state
• TS
(if it is present)
(if it is present)
• year
• Lot
• U1802
• 1065
• 00001
Regulation (EU)
2016/426
PED Directive
2014/68/EU
* Component designed for industrial use in industrial sites.
EV(Q-R-S-T)-1-3-6
= device name/model followed
by the connection diameter
= Seal strength in counterflow at 150 mbar in
accordance with EN 161
= Mechanical resistance group 2 in accordance with EN 161
= Product reference regulation
= Protection rating
= Power supply voltage, frequency (if Vac), followed by electrical absorption
= Temperature range within which product operation is guaranteed
= Conformity with Regulation (EU) 2016/426 followed by Notified Body No.
= Conformity with PED Dir. followed by Notified Body No.
= Year of manufacture
= Product serial number (see explanation below)
= Lot issued in year 2018 in the 2nd week
= progressive job order number for the indicated year
= progressive number referring to the quantity of the lot
P. max 0.5 bar
-
-
-
22
Mod: EVS-6 DN 150
CE- 51CR4682 CI.A GR.2 EN 161
IP65 – 230 V/50-60 Hz 270/70 VA
0051
0497
year: 2018
Lot: U1802
Compliance table
P. max 1 bar
Madas Technical Manual - 1|1.5d - REV. 1 of 10
Via Moratello, 5/7
37045 - Legnago
(VR) - Italy
P.max=PS= 6 bar
TS: -20+60 °C
1065/00001
P. max 3 - 6 bar
*
*
*
Sep 2020
th
Tabla de contenido
loading

Tabla de contenido