5. Allowable stresses
WARNING / BEWARE!
The LX-Strut is inserted through the ratchet when used correctly with
a max. pre-load force of 0,05 to.
when the prop is fully extended.
10-fold safety
on preload force
max. Preload force
0.05 to.
LUKAS Operating Instructions LX-Strut
.
This results in a safety factor of 9
30
1.5-fold safety
on breaking load
max. Load bearing
capacity
2,10 tons.
F1
LUKAS Operating Instructions LX-Strut
max. Load bearing
capacity
0.50 to.
F2