E130
E131
E132
E133
E134
E135
E136
E137
E149
E150
E151
E155
E157
E158
E160
E161
E162
E166
E167
E170
799 GPT Titrino
Wrong sample. For SET, KFT or DOC with preset titration direction
the first measured value lies behind the endpoint.
Exit: The error message disappears on next startup.
No EP set for SET, STAT.
Exit: The error message disappears on next startup.
Silo empty and it has been started with open silo or empty silo has
been opened.
Exit: Send a silo entry.
Silo full.
Exit: Send new command.
No method. A method, which is required from the silo memory or in TIP, does
not exist.
Exit: The error message disappears on next startup.
Check temp.sensor in MEAS T or with activated temperature monitoring.
Exit: Correct error or &m $S.
Same buffer in CAL. Measured value of the second buffer differs less than 6
mV from the measured value of the first buffer.
Exit: Correct error or &m $S.
XXX Bytes are missing so that the method, the silo line could not be stored or
not enough RAM for running TIP.
Exit: Send new command.
Rate missing for calculation.
Exit: The error message disappears on next start or on recalculation.
Number of rates does not agree with the set windows or the mean rate C80
could not be calculated.
Exit: The error message disappears on next start or on recalculation.
Fix volume missing for calculation.
Exit: The error message disappears on next startup or on recalculation.
No new silo result (C24 or C25).
Exit: The error message disappears on next start or on recalculation.
No sequence defined in TIP.
Exit. The error message disappears on next start.
A second TIP has been called up in TIP.
Exit: The error message disappears on next start.
No new temporary variable.
Exit: The error message disappears on next start.
Measurement range of the secondary measured value (temperature)
exceeded. The primary measured value (pH, U, Ipol, Upol) can also be
unstable.
Exit: Rectify error or &m $S.
No ramp end set in DOC.
Exit: The error message disappears on next start or &m $S.
Save lines is "OFF" although a submethod of TIP includes an assignment to
C24 or C25.
Exit: The error message disappears on next start. Attention: The data of this
sample will not be stored.
Rate too high in DOS. No dispensing possible with the Exchange Unit currently
mounted.
Exit: The error message disappears on next start or &m $S.
Fix time missing for calculation.
Exit: The error message disappears on next start or on recalculation.
3.1 General rules
113