This device is recommended for the prevention of basic bedsores in long-term and home therapy.
Skin is delicately massaged at alternating points of contact for improved blood flow and tissue oxygenation to prevent
the formation of bedsore ulcers.
It is easy to install, use and maintain and offers pressure adjustment based on patient weight.
This non-toxic PVC mattress is inflated with its own compressor and supports patients lying down.
Check the correct functioning of the regulator by turning the knob form MIN to MAX.
INTENDED USE
The pump and mattress are intended to reduce the incidence of pressure ulcers while optimizing patient comfort.
It also provides the following:
Individual home care setting and long-term care
Pain management as prescribed by a physician
1.
Particular precautions must be made concerning electromagnetic compatibility. The medical device must be
installed and used according to information supplied with the accompanying documents;
2.
On opening the packaging, check the integrity of the appliance, paying particular attention to the presence of
damage to the plastic parts, which may make access possible to internal live parts and also to breakage and / or
peeling of the power supply cable. In these cases don't connect the plug to the electric socket. Carry out these
controls before each use;
3.
Before connecting the appliance always check that the electric data indicated on the data label and the type of plug
used, correspond to those of the mains electricity to witch it's to be connected;
4.
If the plug supplied with the appliance is incompatible with the mains electricity socket, contact qualified staff for
replacement of the plug with a suitable type. The use of simple or multiple and / or extension adapters is not
generally recommended. Whenever their use is indispensable, use those in compliance with safety regulations,
however paying attention not to exceed the maximum power supply limits, which are indicated on the adapters
and extensions;
5.
Respect the safety regulations indicated for electrical appliances and particularly:
Use original components and accessories provided by the manufacturer CA-MI S.r.l. to guarantee the highest
efficiency and safety of the device;
Never immerge the appliance into water;
Preserve and use the medical device in environments protected from atmospheric factors and at a distance
from heat sources;
Keep off the reach of children or not capable people without supervision;
Don't leave the appliance connected to the power supply socket when not in use;
Don't pull the power supply cable to disconnect the plug remove the plug from the mains socket correctly;
Preserve and use the medical device in environments protected from atmospheric factors and at a distance
from heat sources;
DO NOT use in presence of flammable anesthetics, it may cause explosions. Due to the risk of electric shock, do
not remove the cover (back).
In case of failure and / or malfunction please contact immediately the technical service CA-MI S.r.l. Failure to
comply with the above can jeopardise the safety of the device; None of electric or mechanical parts have been
designed to be repaired by customers or end-users. Don't open the device, do not mishandle the electric /
mechanical parts. Always contact CA-MI technical assistance
6.
This medical device must be destined exclusively for the use for witch it has been designed ad described in
this manual. Any different use must be considered incorrect and therefore dangerous; the manufacturer cannot
be considered liable for damage caused by improper, incorrect and / or unreasonable use or if the appliance is
used in electrical plants that are not in compliance with the regulations in force;
7.
Instrument and accessories discharging must be done following current law regulations in every country of use.
8.
Using the device in environmental conditions different than those indicated in this manual may harm seriously the
safety and the technical characteristics of the same.
KEEP OFF REACH OF CHILDREN OR NOT CAPABLE PEOPLE WITHOUT SUPERVISION
IMPORTANT SAFETY RULES
READ INSTRUCTION MANUAL CAREFULLY BEFORE USE
THE INSTRUMENT MUST NOT BE DISASSEMBLED.
FOR A TECHNICAL SERVICE ALWAYS CONTACT CA-MI S.r.l.