Safety and detection deviceS
Smoke thermocouple
on the smoke outlet. It reads the smoke temperature. It regulates the ignition stage and shuts the boiler-stove down if the tempera-
ture is too high or too
low.
flow sensor
on the combustion air intake pipe. It detects whether the combustion air and outlet smoke are circulating correctly. It returns a vol-
tage signal which may be read on the detector status display. In the event of anomaly (which may be attributed to INcorrect smoke
outlet or combustion air intake), it shuts the stove down.
Screw feeder safety thermostat
near the pellet hopper. It cuts off the power supply to the gearmotor if the temperature measured is too high.
Water temperature detector
It reads the water temperature in the boiler-stove and sends the circuit board information for pump management and boiler-stove
power modulation. if the temperature is too high, it starts a shutdown.
Water overheating safety thermostat with manual reset
measures the temperature of the water inside the thermo-stove. If the temperature is too high, it cuts off the motor's electrical
power supply. In the event that the thermostat has been operated, it must be re-activated by acting on the reset button behind the
boiler-stove (see page. 21).
overpressure valve
upon reaching the pressure stipulated on the plate, the system is triggered to discharge the water and consequently the water must
be topped up.
Warning!!!! remember to carry out the connection with the sewage system.
manometer
Located under the ceramic top, it allows to read the water pressure of the stove with the thermal boiler-stove running, the recom-
mended pressure is 1bar.
if the thermal boiler-stove blocKS, the reaSon Will appear on the diSplay and thiS
Will be Saved.
componentS
resistance
It sets off of the combustion of the pellets and it remains lit until the flame has been ignited.
Smoke extractor
"pushes" the smoke into the flue and draws out combustion air via a vacuum.
gear motors
activates the feed screw, which allows the pellets to be transferred from the hopper to the combustion chamber.
pump (circulator)
"pushes" water toward the heating system.
closed expansion tank
"absorbs" the variations in the volume of water contained inside the thermo-stove due to the heating effect.
Aheating technician must evaluate the need to add a second tank to the existing one, depending on total amount of water in the
system.
venting valve:
positioned in the upper part, it allows for the "bleeding" of any air present during the loading of water inside the boiler-stove.
drain tap
placed inside the lower part of the thermal boiler-stove. This is to be opened if the water inside the thermal boiler-stove must be
emptied.
- 6
-