TROUBLESHOOTING
Problem
Burner will not light.
Burner will not stay lit.
Burner flame is low
Note: Do not operate
appliance below 5 ˚C
Condition
Control knob is not in
maximum position (big
flame).
LPG cylinder valve is
closed /empty
Blockage in the injector.
Air in the gas circuit.
Low gas pressure.
Igniter fails.
Dirty build up around
burner.
Low flames or not full
running around the burner.
Thermocouple is not
operating correctly.
Low Gas pressure.
Outdoor temperature is
greater than 5 ˚C and LPG
cylinder is less than 25
% full.
Gas pipe is bent or kinked.
Control knob is fully
maximum position (big
flame).
Solution suggested
Turn control knob in
maximum position (big
Open the valve / Replace
LPG cylinder with a new
one.
Clean or replace injector.
Open gas line and bleed it
(pressing control knob in)
for not over 1 minute or
until you smell gas.
Replace LPG cylinder with
a new one.
Use match to light burner;
change battery or obtain
new ignite and replace it.
Clean dirty around the
burner.
Flame spreader holes
partially closed; clean the
burner.
Replace thermocouple
(FSD).
Replace LPG cylinder with
a new one.
Replace LPG cylinder with
a new one.
Straighten hose and
perform leakage test on
gas pipe.
Turn control knob to"OFF"
position (full disk), let cool
to room temperature and
check burner and orifices
for blockage.