Installation Instructions – CD61*/CD62*/CD6S* Commercial
Recessed CFL Rough-In
Instructions d'installation – Nécessaire d'installation brute LFC
encastré commercial CD61*/CD62*/CD6S*
Instrucciones de instalación para la luminaria fluorescente compacta
empotrada de uso comercial en área oculta CD61*/CD62*/CD6S*
IMPORTANT: Read carefully before installing fixture. Retain
for future reference.
WARNING
Risk of Electrical Shock! Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Fire! Do not install insulation within 3 inches
(76 mm) of any part of the luminaire fixture or in a way
that may entrap heat.
N
otee:
This fixture should be supported by main runners or
other structure that is capable of supporting fixture
weight of 10 Ibs.
IMPORTANT SAFEGUARDS: When using electrical
equipment, basic safety precautions should always be
followed, including the following:
SAFETY INSTRUCTIONS
1.
This unit is for recessed mounting only. Do not use in
hazardous locations nor near gas or electric heaters.
2.
Do not use this equipment for other than the intended
use. (Figure 1.)
3.
Install only in accordance with National Electrical Code
and local regulatory agencies' requirements.
INSTALLATION
To Install Rough-In Sections
1.
Install fixture into ceiling cavity using 1/2˝ electrical
conduit. Use 3/4˝ channel, 1-1/2˝ channel, 1/8˝ x 1/2˝
bar stock, or T-bar fasteners as mounting rails (furnished
by others) by inserting the through hanger brackets at
both sides.
WARNING
Installation and servicing to be performed only
by qualified personnel. If not qualified, consult an
electrician.
Figure 1.
Aperture
CD61*/CD61*/CD6S*
TM
INS #
Ceiling Cutout
6-3/8"
7-1/4"
Tabla de contenido
loading

Resumen de contenidos para Eaton Cooper Lighting PORTFOLIO CD61 Serie

  • Página 1 INS # ADP140615 Installation Instructions – CD61*/CD62*/CD6S* Commercial Recessed CFL Rough-In Instructions d’installation – Nécessaire d’installation brute LFC encastré commercial CD61*/CD62*/CD6S* Instrucciones de instalación para la luminaria fluorescente compacta empotrada de uso comercial en área oculta CD61*/CD62*/CD6S* WARNING IMPORTANT: Read carefully before installing fixture. Retain for future reference.
  • Página 2: Trim Installation

    2-18W 1-32W 2-26W 1-42W 6CH142W* 1-13W 6CS226W* 2-13W 1-18W 2-18W 1-32W 2-26W 1-26W 6CLS142* 1-13W 1-26W 1-18W 1-26W 1-26W 1-42W 1-26W 1-32W 1-42W 6CLS226* 2-13W 2-18W 2-26W Figure 4. Installation Instructions – CD61*/CD62*/CD6S* Commercial Recessed CFL Rough-In 705300INS ADP140615 www.eaton.com...
  • Página 3 Electrical Wiring Diagrams LINE BLACK WHITE NEUTRAL 2-LAMPS 1-LAMP GREEN/BARE COPPER GROUND YELLOW BLACK YELLOW BLUE HOT - BLACK BLUE BLUE NEUTRAL - WHITE BLUE WHITE BALLAST BALLAST Figure 7. Installation Instructions – CD61*/CD62*/CD6S* Commercial Recessed CFL Rough-In 705300INS ADP140615 www.eaton.com...
  • Página 4: Précautions Importantes

    Connectez les fils de sortie d'alimentation aux fils de sortie du ballast selon le schéma de branchement et conformément aux codes électrique locaux ou au code Figure 2. national de l'électricité. Instructions d’installation – Nécessaire d’installation brute LFC encastré commercial CD61*/CD62*/CD6S* 705300INS ADP140615 www.eaton.com...
  • Página 5 1-13 W 1-26 W 1-18 W 1-32 W 1-32 W 1-42 W 1-26 W 6CLS226* 2-13 W 1-26 W 2-18 W 1-26 W 2-26 W 1-42 W Instructions d’installation – Nécessaire d’installation brute LFC encastré commercial CD61*/CD62*/CD6S* 705300INS ADP140615 www.eaton.com...
  • Página 6 Schémas de branchement électrique 2 LAMPES 1-LAMPE ROUGE ROUGE ROUGE ROUGE JAUNE NOIR JAUNE BLEU COURANT - NOIR BLEU BLEU NEUTRE - BLANC BLEU BLANC BALLAST BALLAST Figure 7. Instructions d’installation – Nécessaire d’installation brute LFC encastré commercial CD61*/CD62*/CD6S* 705300INS ADP140615 www.eaton.com...
  • Página 7: Medidas De Prevención Importantes

    Código Eléctrico Nacional. Figura 2. Instrucciones de instalación para la luminaria fluorescente compacta empotrada de uso comercial en área oculta CD61*/CD62*/CD6S* 705300INS ADP140615 www.eaton.com...
  • Página 8 1-32 W 1-32 W 1-42 W 1-26 W 6CLS226* 2-13 W 1-26 W 2-18 W 1-26 W 2-26 W 1-42 W Instrucciones de instalación para la luminaria fluorescente compacta empotrada de uso comercial en área oculta CD61*/CD62*/CD6S* 705300INS ADP140615 www.eaton.com...
  • Página 9 ROJO ROJO ROJO AMARILLO AMARILLO NEGRO AZUL VIVO - NEGRO AZUL AZUL NEUTRO - BLANCO AZUL BLANCO BALASTO BALASTO Figura 7. Instrucciones de instalación para la luminaria fluorescente compacta empotrada de uso comercial en área oculta CD61*/CD62*/CD6S* 705300INS ADP140615 www.eaton.com...
  • Página 10 All trademarks are property Eaton’s Cooper Lighting Business of their respective owners. 1121 Highway 74 South Peachtree City, GA 30269 Eaton est une marque de commerce Cooperlighting.com déposée. Toutes les autres marques de commerce sont la propriété de leur © 2014 Eaton propriétaire respectif.

Tabla de contenido