swissflex uni 22 95RF bridge Modo De Empleo página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Disable the sync function by pushing the „Sync function"
button (17).
The entire remote control flashes twice (blue) once the
sync function has been successfully disabled.
Under-floor lighting
Activate the under-floor lighting by pushing the „Un-
der-floor lighting" button (8). This switches off auto-
matically after 30 minutes, or if the button is pushed
once again. This button is illuminated (blue) when it is
pushed.
Pocket lamp
The pocket lamp is illuminated when the „Pocket lamp"
button (5) is held down. The light turns off when the
button is released. This button is illuminated (blue)
while the pocket lamp is in use.
Lock buttons
To lock the buttons, hold down the „Lock buttons" but-
ton (20) for five seconds. Once the button lock has been
activated, all buttons (except for the mains outlet (19),
the pocket lamp (5), the under-floor lighting (8) and the
button lock (20)) flash (blue) twice.
All buttons flash twice (white) when a disabled button is
pushed. The lock is disabled by holding down the „Lock
buttons" button (20) for five seconds. All buttons flash
twice (blue) if this was successful.
Adjustment options
The sleep and sit positions have been pre-program-
med in the factory.
M1 Read and watch TV without getting tired
M2 Relieving position for colds, respiratory disorders
or cardiovascular complaints
M3 Ergonomic position for backaches and invertebral
disk complaints
M4 Aids for getting into and out of the bed
The positions can be overwritten individually.
Resetting the factory-programmed memory positi-
ons
Hold down the memory button (18) for 3 seconds – the
background lighting then flashes once, the under-
floor lighting button (8) must then be pressed within
a second. The entire RF-Touch lighting flashes twice
to confirm that the factory settings have been reset.
Saving the sitting and lying position to a memory
button
1. Press the memory button (18) 3x within 2 seconds.
2. The memory button is illuminated (blue) (1–4).
14
Operating instructions
3. Press the desired memory button for memory po-
sition 1–4 (1–4) 1x within three seconds.
4. The programming of a new position automatically
overwrites an old position. A successful save is
visualised by a change in colour of the selected
memory button LED (white). All memory buttons
turn white two seconds after the memory button is
released.
To call up a position stored in memory
Press the desired memory button for memory position
1–4 (1–4), until all the comfort sections have reached
the programmed position. The activated memory but-
ton is illuminated (blue) during the travel time.
To reset to the horizontal position
Press the "all motors down" button (7) to simulta-
neously move all sections to the horizontal position.
Care and Maintenance
Your uni 22_95 RF is a high-quality product that has been
designed to serve you reliably for many years to come.
For occasional cleaning and the removal of dust, we
recommend the use of a dry cloth.
Changing the batteries in the radio remote control
Remove the cover from the battery compartment (21)
on the back of the radio remote control. Place three
AAA batteries into the compartment, paying attention
to the +/- markings. Close the compartment cover
again.
Changing the batteries (22) in the uni 22_95RF swit-
ching power supply (batteries for emergency lowe-
ring)
Carefully remove the batteries from the battery clips.
Place two 9V block batteries in the compartment, pa-
ying attention to the +/- markings. The batteries in the
switching power supply provide power in the case of
a power failure.
Troubleshooting
In case of malfunctions with your uni 22_95RF, con-
sult the following troubleshooting tips. If the problem
Technical data
Supply voltage: 110-240V
Remote control power supply: 3x AAA Batteries
Power rating motors: Intermittent operation FROM
2 min / 18 min
Power rating user socket : 850 W
User socket fuse: 5x 20 mm T 4A
Thrust motors: 4x 3000 N
Power supply for emergency lowering: 2x 9V block bat-
tery
cannot be resolved, disconnect the uni 22_95RF from
the mains outlet and contact your Swissflex stockist.
Loss of power in the sitting position
In case of a power failure, a battery pack (2 x 9V) is lo-
cated in the switching power supply connected to the
motor control, which allows you to move the bed to
the flat sleeping position. Use the "all motors down"
button (7) to move the bed to the horizontal position
when there is no mains power.
The uni 22_95RF does not work despite being swit-
ched on and all components being connected pro-
perly
Disconnect the mains supply unit from the mains out-
let. Wait a minute and then reconnect it. If necessary,
connect a bedside lamp to check that mains voltage
(240V) is present. If there is no current, check the
fuse.
Press the "all motors down" button (7) to reset all
adjustments. The control of the uni 22_95RF contains
microprocessors, so irregular power supply can lead
to malfunctions.
The radio remote control does not work (The back-
ground light does not work)
Insert new batteries. Where applicable, remove any
obstacles between the radio remote control and the
motor control.
After a power failure
Before resuming use of the uni 22_95RF, press and
hold the "All motors down" button (7), until all com-
fort areas have reached the horizontal position and
the motors have stopped moving.
Problem
Possible cause
Remote control or
No mains supply.
control system not
Manual switch or control system defective.
working.
Switched capacitor or mains isolation blank.
Control systems
Thermoswitch on the transformer may have
suddenly no longer
been triggered or may be defective.
travel / move.
Thermal cut-out in the transformer may have
been triggered or may be defective.
Internal fuse may have been triggered or may
be defective.
No mains supply.
Supply line (mains and / or manual switch /
auxiliary control system) interrupted.
The battery-operated
Block battery / block batteries flat.
electric reset function
Block battery/batteries not connected.
cannot be activated.
GB
GB
Emergency lowering
The emergency lowering function allows the bed's
sleeping surface to be moved to the sleeping position
in case of a power failure.
1. Press the "emergency lowery button" (31) on the
motor control.
Repeated use of the emergency lowering function
puts a lot of strain on the batteries, in which case
they must be replaced.
Solution
Restore mains connection.
Contact your supplier / stockist.
Press the button on the mains isolation plug.
Leave the control system in the rest position for 20-30 minutes.
Contact your supplier / stockist.
Contact your supplier / stockist.
Restore mains connection.
Check the supply line and restore contact if applicable.
Check and replace the block battery / block batteries if necessary.
Connect the block battery / block batteries.
Operating instructions
15
Tabla de contenido
loading

Tabla de contenido