Complete the Installation (cont.)
Place the handle in the vertical position, as shown.
Rotate the handle clockwise, then reposition the handle at the 2
o'clock position.
For hot and cold water supply installations: Rotate the handle as
needed to achieve the desired water temperature.
For tempered or filtered water installations: Turn the handle
counterclockwise to the full cold position.
Secure the cover and handle to the valve with two screws
(provided).

7. Troubleshooting

Symptoms
Probable
Causes
1.
No water
A. There is a
flow.
B. The
C. The
1056542-2-B
Recommended Action
A. Remove the valve cover and
loose
check the connections from the
connection.
battery to the solenoid and
from the battery holder to the
sensor. Make sure that the
connector arrows are aligned
and that the connection is
secure.
B. Confirm the supply stops are in
the "ON" position.
supply
stops are
in the
"OFF"
position.
C. Remove the cover and inspect
wires/cables
the wires/cables for cuts or
are
damage. If the wires are cut or
pinched or
damaged, order a new
damaged.
solenoid, sensor assembly,
sensor extension cable, or
battery holder. Do not pinch or
damage the wires during
reassembly.
10
Kohler Co.