CPS Models
BATTERY CHARGER STAGE
Nominal voltage
(6)
Maximum recharge current
Input voltage tolerance for recharging at
maximum current
MODES AND EFFICIENCY
Operating modes
AC/AC performance in on line mode
AC/AC performance in Eco mode
SIZE AND WEIGHT
W x D x H
Weight
OTHER FEATURES
Noise
Colour
(7)
Ambient temperature
(1)
@ 100% load & THDv ≤ 1%
(2)
In order to keep the output voltage within the indicated precision range, a recalibration may be necessary, following a long period of use.
(3)
If the mains frequency is within ± 5% of the selected value, the CPS is synchronised with the mains. If the frequency is out of the tolerance
range, or in battery operation, the frequency will be the selected +0.01%
(4)
Mains/Battery @ 0% -100% load
(5)
@ Mains / battery / mains @ 0% / 100% / 0% resistive load
(6)
The recharge current is adjusted automatically, depending on the capacity of the battery installed.
(7)
20 – 25 °C for a longer battery life
CPS 20
240Vdc
10A
345-480Vac
ON LINE
ECO
EMERGENCY ONLY
Up to 96.5%
 99%
440 x 850 X 1320 mm
135kg
≤ 48dB(A)
RAL 7016
0 – 40 °C
115
CPS 30
145kg