Wallbox DYNAMIC POWER SHARING Manual De Instrucciones página 52

Tabla de contenido
Primary Charger
Configuration
1.
Number of Chargers:
Input the number of chargers including
the Primary charger
2.
Maximum current per phase:
It is the maximum current that can be
supplied to the charging network. This
value is usually the rated current of the
MCB
3.
Minimum current per charger:
From 6 A to 10 A. The default value
is 6 A
4.
Mains Breaker Maximum current:
The maximum current that can
be supplied to the electrical installation.
This value is the rated current of the
mains circuit breaker that protects the
electrical installation.
Tabla de contenido
loading

Tabla de contenido