RIB PRESIDENT 3M Manual Del Usuario página 30

Ocultar thumbs Ver también para PRESIDENT 3M:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G
B
J18
J1
N F
Power supply 230 Vac 50/60 Hz - external to the control panel -
(120 V 60 Hz upon request)
J2
SECONDARY
Connectors for secondary 18 Vac transformer
TRANSFORMER
J3
BATTERY CHARGER
Connector for 24V battery charger board (code ACG4774
(24 V DC SOLAR
optional)
J4
MOTOR
Connector for 24 Vdc motor and 5 Vdc encoder
J5
Connector for flasher 24 Vdc (cod. ACG7072)
Pay attention to the polarity.
DO NOT DRILL THE OPERATOR'S HEAD TO FIX THE FLASHING LIGHT!
J6
A+ COM
+ 24 Vdc accessories power supply
A-
- 24 Vdc accessories power supply
A+TEST
+ 24 Vdc photocells self-test power supply
J7
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Barrier opened warning light, operating signal with battery and
low battery (24 Vdc 3W max)
COM A+
Contacts common / Positive 24 Vdc
J8
PHOTO 1
Photocells contact 1 (NC)
PHOTO 2
Photocells contact 2 (NC)
STOP
STOP impulse contact (NC)
TLC
Magnetic sensor contact for traffic light control in PARK mode
COM A+
Common contacts / Positive 24 Vdc
J9
SECURITY LOCK
Connector for manual release switch
(factory connected - DO NOT REMOVE!)
J1
J2
F1
J3
J17
J16
J15
F
N
J4
J5
J6
J10
OPEN 1
OPEN 2
CLOSE
START
B.I.O.
OK CLOSE
COM A+
J11
J12
APP+
J13
APP
J14
SERIAL COM /SYNC Connector for serial connection
J15
RADIO
J16
RADIO
J17
J18
AUX CARD
RUN
TCA
LOW SP.OP.
LOW SP.CL.
PROG
F1
T 2 A
F2
F10 A
30
J7
J8
J14
J12
J13
Opening impulse contact (NO) - to enter
Opening impulse contact (NO) - to exit
Closing impulse contact (NO)
Single pulse contact (NO)
Contact (NO) dedicated to a timer
Contact for closing confirmation in PARK mode
Common contacts / Positive 24 Vdc
RS485 termination of J12
Connector for APP+ card
Connector for APP card
Connector for radio receiver RIB, 24 Vdc supply
Connector for radio module ACG8069
433 MHz Radio antenna
Card 1 relay connector (code ACQ9080) for management of
courtesy light.
Card 3 relay connector (code ACQ9081) for management of
courtesy light or traffic lights.
Trimmer for high speed adjustment operations
Trimmer for automatic closing time adjustment (By factory
DISABLED AND DL9 LED OFF)
Electronic regulator for low speed on approach in opening
Electronic regulator for low speed on approach in closure
Programming button
Transformer protection fuse (external to the card P1 24V)
Fuse for motor protection
J9
J10
J11
Tabla de contenido
loading

Este manual también es adecuado para:

President 4mAa50091Aa50092Aa50093Aa50094

Tabla de contenido