PROTEOR 1S162 Instrucciones De Uso página 3

Idiomas disponibles

Idiomas disponibles

I PACK CONTENTS
One assembled valve (1) including:
One valve seat (1.1)
One valve plug (1.2) including :
> one cap (1.21)
> one flap (1.22)
> one membrane (1.23)
One flat gasket (2)
A fastening system for flexible socket including :
> one insert (3.1)
> two nails (3.2)
> one internal gasket (3.3)
This instruction sheet.
II USE
The 1S162 valve is intended for use in lower limb prosthesis only. Any other use is not permitted.
The 1S162 valve is designed to allow automatic air expulsion during prosthesis donning.
To remove the prosthesis, press button (1.22) (See chapter I) to allow air to flow in.
III INDICATIONS / CONTRA-INDICATIONS
No contra-indications for using the 1S162 valve in a lower limb prosthesis, whatever the patient weight and activity level.
IV MAKING THE SOCKET
Rigid socket :
Make the socket as usual and mark the
a)
position of the valve on this socket.
Then drill a 8.5 mm Ø hole on the lankmark,
perpendicular to the socket wall.
b)
Thread the hole at M10 x 1.5.
Flexible socket :
Before thermoforming, fasten insert (3.1)
(smooth face on the outside) to the positive
using the 2 nails (3.2.)
* Drill a 10,5 Ø hole into the socket
(Threading the soft material is impossible)
V PREPARING THE VALVE
a)
Disassemble the valve plug (1.2) and the
valve seat (1.3), then place the flat gasket
(2) on the valve seat.
b)
Using a 5 mm hex wrench (3), screw the
valve seat (1.1) into the socket and take
care that the flat gasket (2) be compres-
sed enough.
1S162 VALVE FOR BK SOCKET
INSTRUCTIONS FOR USE
a)
2
a)
3
3.
1
3.
3.
2
3
1.
2
1.
1
6, rue de la Redoute - 21850 - SAINT APOLLINAIRE -FRANCE
Tél: 33 (0)3 80 78 42 10 - Fax: 33 (0)3 80 78 42 15
[email protected] www.proteor.com
1S16299-04/17
2
1
1.
2
1.
1
1.
23
b)
2
1.
1
b)
PROTEOR
3/8
1.
21
1.
22
3
loading