Settings; Operator Settings; Weight Setting; Machine Setting - Bosch WBE 4510 Instructions De Réparation

Ocultar thumbs Ver también para WBE 4510:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

en
30 | WBE 4510 - WBE 4515 | Settings
4.

Settings

From the start page select SETUP, then select the set-
ting menu; use the DOWN and RIGHT ARROW keys to
move in the menu and use OK key to confirm.
4.1

Operator settings

Fig. 2:
SETUP OPERATOR button
Press the SETUP OPERATOR key to enter in the opera-
tor settings.
Description
...
Language selection: high-
light and press OK key.
Activation/deactivation of the wheel
protection cover for the launch.
Activation/deactivation of
the screen protection.
Activation/deactivati-
on of the acoustic signal.
!
Warning: with the software in use it is possible to
update in any moment the language used, so if it is
necessary to install a new language, contact SICAM,
it will provide updating instructions.
4.2

Weight setting

Fig. 3:
SETUP WEIGHTS button
Press the SETUP WEIGHTS to enter the weight settings.
Description
Selection of the measu-
re unit: grams or ounces.
Selection of imbalances dis-
play: real or rounded up values.
Setting of the machine zeroing.
|
1 695 655 167
2014-01-13
4.3

Machine setting

Fig. 4:
SETUP MACHINE button
Press the SETUP MACHINE button to enter the machine
settings.
Description
Selection of the manual or au-
tomatic run-out reading func-
tion during launch.
Activation/deactivation of the
wheel width measurement.
Activation/deactivati-
on of the internal gauge.
Selection of the measu-
re acquisition mode „aluda-
ta": pedal or automatic.
Setting weight positioning with the
arm or in the chosen positions.
4.4

Calibration menu

The calibration procedure of the balancer is divided
into three different parts:
R
Calibration of the flange
R
Calibration of the electronic gauges
R
Self-calibration with wheel and sample weight
The calibration of the flange stores the unbalance value
of the shaft and wheel adapter. It is suggested to per-
form flange calibration in the following cases:
R
when, running a launch without the wheel, the ma-
chine finds imbalances greater than 5 grams;
R
when you change type of flange (motorbike flange,
cone flange or 3\4\5 holes).
Fig. 5:
CALIBRATION button
Robert Bosch GmbH
Tabla de contenido
loading

Este manual también es adecuado para:

Wbe 4515

Tabla de contenido