TROUBLESHOOTING

Symptom
Machine does not start
when the switch is in"
I"position.
Machine pressure is
not consistent.
The pressure of the
pump is not adequate
No detergent
Lance leaks
12 12
Electric Pressure Washer
Possible causes
Power cord is not plugged in.
Socket is defective.
GFCI is triggered.
Pump is faulty.
Air in line.
Water inlet adapter is clogged or dirty.
Water supply is Insufficient.
Water supply is restricted.
Diameter of garden hose is too small.
Leak or kink in hose .
Wrong nozzle is attached
O-ring needs to be replaced.
Solution
Plug in power cord.
Check or replace plug, socket, fuses.
Press reset on GFCI plug.
Contact service center .
Remove the nozzle, turn on the machine and allow low
pressure water to flow for a while and install the nozzle
back.
Remove the adapter, rinse it with water and put is back.
Open water source completely.
Check If the water hose kinks or leaks.
Replace with right garden hose .
Replace hose or untie kinks in hose.
Attach the soap nozzle
Replace O-ring .If the problem is not solved ,contact
service center to buy a new lance.