Installation (continued)
Twist and break off the plastic cover (1) from the
plaster guard (H) and discard.
Remove the valve cap (2) from the valve body (I).
H
2
1
Turn the valve counterclockwise to the full position.
After several minutes, check the temperature using
the thermometer.
Slowly turn the valve clockwise to adjust the maximum
water temperature to the desired temperature.
CAUTION: The maximum water temperature should never
be set above 120°F (49°C).
Turn on the water supply, and then turn on the valve
to check all connections for leaks.
I
c
b
8
a
c
a
120°F
(49°C)
b
Tabla de contenido