NOTE
If the control lock is active (illuminated lock icon) the control
will have to be unlocked before using the keypad to reset
an alarm condition. See page 12 (Control Lock) for
instructions for unlocking the control.
Temperature Sensor Error Codes
The temperature sensors are monitored continuously. Any
OPEN or SHORTED circuit condition will initiate an
ERROR CODE as listed below:
Single Zone Models:
Alarms (Single and Dual Zone):
The control will alert you to conditions that could adversely
affect the performance of the appliance.
Sensor
Single Zone
Temperature Sensor
Defrost Sensor
Dual Zone Models:
Door Ajar
USING YOUR ELECTRONIC CONTROL
Temperature Sensor Error Codes
Displayed Code
Failed temperature sensor in the single
unwanted wine storage temperatures.
Causes unit to not defrost properly and
can create large frost build-up. Can lead
ALARM RESET
•
Door ajar -
properly, for more than 5-minutes the System Status
OK indicator will turn-off, the "Door Ajar" indicator will
flash, and a tone will sound every 60 seconds.
Additionally, an "ALARM RESET" indicator will be
displayed below the "On/Off" keypad.
The audible alarm can be muted, for each occurrence,
by pressing the lock keypad.
This alarm condition can be reset by closing the door
or momentarily pressing the "On/Off" keypad, (i.e.-if
you are cleaning the storage compartment, etc.). The
alarm will recur in 5-minutes if the alarm condition
persists.
Error Description
zone compartment. Can lead to
Failed defrost temperature sensor.
to water damage to the unit and
surrounding floor.
14
If the door is open, or not closed
NOTE
Action to Take
Call service to have the
temperature sensor replaced.
Unplug the power cord
immediately and call service to
have the defrost sensor
replaced.