Secure the bracket [9-2] to the ceiling
via the four holes [9-1]. Use fasteners
suitable for the relevant building material
(e.g. tie rods, dowels).
Skip to chapter 8 "Connections in the EAA".
8

Connections in the EAA

8.1

Connecting the control cable

Wind the excess cable onto the holder [5-
10].
Place the flat seal supplied [10-1] over
the cable connector [5-2] in the EAA.
Insert the contact box [10-2] into the ca-
ble connector [5-2] and tighten the screw
[10-3].
Secure the control cable under the strain
relief on the EAA [5-3].
8.2

Connecting the mains cable

Wind the excess cable around the ridged
section [5-6].
Place the flat seal supplied [10-6] over
the contact box [5-7] in the EAA.
Insert the contact box [10-5] into the ca-
ble connector [5-7] and tighten the screw
[10-4].
Secure the mains cable under the strain
relief on the EAA [5-4].
Plug the mains cable on the EAA into an
earthed socket with a 16 A fuse.
Exception: If the connected dust extrac-
tor is from another manufacturer, a differ-
ent configuration may be more appropri-
ate - see chapter 9.1 "Mobile dust extrac-
tor".
On country versions GB, CH and DK, the
plug on the mains cable for the EAA/ASA
must be removed and replaced with the
accompanying rewirable plug. Note: only
trained and qualified electricians are au-
thorised to perform this work!
8.3
Connecting the compressed air
line
Applies only for ASA mounting and ceiling
installation.
Cut the grey compressed air line to the
correct length.
EW versions: Guide the air hose through
the housing [11-1] onto the hose con-
nector [11-3] and close the screw
clamp[11-2].
EW/DW versions: Slide the grey air
hose onto the hose connector at the
maintenance unit inlet [7-3] and close
the screw clamp [7-2].
Secure the compressed air line and the
mains power and control cable to the alu-
minium pipe [12-2]using the three grip-
per clamp supplied [12-1].
Insert the end of the blue hose into the
connection[5-1] and guide the hose
through the opening on the housing.
Once you have attached all the connec-
tions inside the EAA, mount the rear panel
on the EAA.
Push the blue air hose onto the elbow
piece [2-5] on the maintenance unit.
8.4
Mounting the hose holder
The hose holder is used to store consumable
materials and hoses. Attach the two hose
holders to the rear panel of the EAA (see Fig.
[13]).
Secure the hose holder [13-4] by screw-
ing an Allen screw [13-2] with washer
[13-3] into both holes using the Allen key
[13-1] supplied.
Secure the rear panel to the EAA using the
screws supplied.
9
Connecting the dust extrac-
tor
A mobile dust extractor or the stationary
TURBO extraction system can be used to ex-
tract dust.
9.1
Mobile dust extractor
CT mobile dust extractors, series CT 22,
CT 33, CT 44, CT 55
Fit the assembly set (module EAA CT22/
33/44/55: 495756) for the control cable
to the CT mobile dust extractor (see as-
sembly instructions).
CT mobile dust extractor series CT 26,
CT 36, CT 48
Fit the assembly set (module EAA CT26/
36: 496143) to the CT mobile dust extrac-
tor (already fitted on CTM 36/48 LE and
CTL 36/48 LE models).
Plug the control cable into the socket on
the extractor.
EAA
GB
21