6:
Automatic Reset-4:
Count value is added to total value
when manual reset is active in
COUNTER/TOTALIZER COUNTER
functions.
7:
Automatic Reset-5:
Count value is added to total value
when manual reset is active in
COUNTER/TOTALIZER COUNTER
functions.
: Input Signal Reset Time (Time Out)
Actual count value is reset if no signal is applied to Ch-A input for a time which is
bigger than the value is set in this parameter.
It can be adjusted from
: Measurement Period
Number of pulses in Ch-A input is counted during this time.
It can be adjusted from
: Output-1 Function
0 :
Output is latched
1 :
Non-latched with hysteresis output is selected.
2 :
Output-1 is an alarm output.
: Output-2 Function
0 :
Output is latched
1 :
Non-latched with hysteresis output is selected.
: Alarm Functions for Output-1
If Output-1 function parameter
Output-1 becomes active according to this parameter.
High Alarm
Output-1
ON
OFF
to
to
. (Latching).
. (Latching).
is selected
Set1-Hys1
Set1
Reset
Set2
Set1
0
Out-1
Out-1
Out-2
Reset
Set2
Set1
0
Out-1
Out-2
seconds.
seconds .
alarm output, then
Count Value
=
=
=
=
=
=
=
10