DSP-EM
NOTE
The service codes from S-15 up to and including S-21 must only be used if you
are not using a battery sensor.
Service code
S-15
End-of-charge voltage Sets the end-of-charge voltage.
S-16
Float charge voltage
S-17
Bulk timer
Duration of the I phase
S-18
Absorption timer
Duration of the
U0 phase
S-19
Battery cable length
S-20
Cable cross section
S-21
Emergency vehicle
charging mode
EN
Description
Note:
Observe the information from the
battery manufacturer
Sets the float charge voltage.
Note:
Observe the information from the
battery manufacturer
Sets the maximum time during which the
battery is charged with maximum
current.
Sets the maximum time during which the
battery is charged with the
end-of-charge voltage.
Sets the length of the cable between the
battery and the DSP-C inverter in order
to compensate for the voltage drop.
Note:
Incorrect values can damage the battery
Sets the cable cross section in order to
compensate for the voltage drop.
Note:
Incorrect values can damage the battery
Switches the emergency vehicle
charging mode ON/OFF.
Stand
Range
ard
value
13.5 V to 15 V
14.4 V
in 0.1 V intervals
12.8 V to 14.3 V
13.6 V
in 0.1 V intervals
0.5 h to 20 h
8 h
in 0.5 h intervals
0.5 h to 10 h
6 h
in 0.5 h intervals
0.1 m to 5 m
0.1 m
in 0.1 m intervals
2
2
2
16 mm
, 25 mm
,
95 m
2
2
35 mm
, 50 mm
,
2
2
70 mm
, 95 mm
ON, OFF
OFF