GENERAL INFORMATION
A.
Your portable gas-fired infra-red heater comes fully assembled
and is tested at the factory for proper gas and input as stated
on the nameplate.
B.
Each heater is equipped with a 100% safety shutoff, push
button valve which will automatically stop the flow of gas in
the event the heater fails to operate for any reason. A tip over
C.
Before proceeding with this installation, be sure to inspect
for damages. The freight company must be notified of any
damages and request that an inspection be made. Enerco
Technical Products will send replacements for damaged parts
only after receiving a signed inspection report to prove the
liability of the freight company.
FOR SAFE OPERATION
1.
READ THESE INSTRUCTIONS CAREFULLY. Read and
adhere to these instructions. DO NOT allow anyone
who has not read these instructions to assemble, light,
adjust or operate this heater.
2.
LP-Gas IS HIGHLY FLAMMABLE.
LP-Gas will accumulate and the possibility of a fire is present.
LP-Gas is scented and its strong odor is readily detectable.
area thoroughly, move the heater outside, and correct the
3.
Keep children and pets away from the heater.
damaged heater.
5.
DO NOT modify the heater or operate a heater which has
been modified from its original condition.
6.
Use only propane gas.
7.
Use only VAPOR WITHDRAWAL propane supply. If there is
dealer.
from damage.
9.
DO NOT
within 20 feet of the heater.
10. IMPORTANT Use only the hose and regulator assembly
provided with the heater. Replace only with factory approved
components..
1 1. This heater is primarily intended for temporarily heating of
buildings under construction, alteration or repair. Area must
be well ventilated. Never use in an occupied dwelling.
12. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor Fade and Propane
Sheet for additional information about detecting propane
13. Install the heater such that it is not directly exposed to water
spray, rain and/or dripping water.
15. Due to the high surface and exhaust temperatures, adults and
16. Operate only on a stable, level surface.
17. DO NOT connect to an unregulated propane source.
19. DO NOT use heater on finished floors.
20. Use only in accordance with local codes or, in the absence of
INSTALLATION INSTRUCTIONS
GENERAL
For the U.S. and/or Canada, the installation of this appliance must
comply with local and/or Provincial codes or, in the absence of
these codes,
inspected before each use and at least annually by a qualified
DO NOT operate a
of excessive abrasion or wear, or if the hose is cut, it must
be replaced prior to the heater being put into operation. The
replacement hose assembly shall be that specified by the
manufacturer. See the parts list.
The minimum ambient temperature rating for this heater is 20
degrees F.
shuts off the burner in the event of tipping. Ensure that this switch
is in the vertical position and is secured with the screws provided.
DO NOT operate this heater with the LP-gas supply cylinder
in any other than the upright position.
3
children must observe clearances to avoid burns or clothing
ignition.
DO NOT move, handle or service while hot or burning.
local codes, with the Standard for the Storage and Handling
Natural Gas and Propane Installation Code.
INSTALLATION CODES.