NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Any safety screen or guard removed for servicing the
appliance must be replaced prior to operating the heater.
The appliance should be inspected before each use.
Frequent cleaning may be required. The control
compartments, burner(s) and circulating air passageways
of the appliance must be kept clean, see MAINTENANCE.
DO NOT use this heater if any part has been under water.
Immediately call a qualified service technician to inspect
the heater and to replace any part of the control system
and any gas control, which has been under water.
When used without adequate combustion and
ventilation air, this heater may give off excessive
CARBON MONOXIDE, an odorless, poisonous gas.
Some people - pregnant women, persons with heart
or lung disease, anemia, those under the influence of
alcohol, those at high altitudes - are more affected by
carbon monoxide than others.
When heater is placed on the ground, make sure
the ground is level and keep any objects at least 24
inches from the front of the heater. THIS HEATER IS
EQUIPPED WITH A TIP OVER SWITCH THAT WILL SHUT
THE HEATER OFF IF THE HEATER TIPS OVER HOWEVER,
DO NOT LEAVE HEATER UNATTENDED OR WHERE
CHILDREN MAY CAUSE THE HEATER TO TIP OVER.
NEVER OPERATE THE HEATER WHILE SLEEPING!
F273699 - Fuel Filter accessory used with
hose assemblies
Accessory Not Included

GENERAL INFORMATION:

This heater is safe for indoor use in small recreational
enclosures, having means for providing combustion air
and ventilation, such as enclosed porches, cabins, fishing
huts, trailers, tent trailers, tents, truck caps and vans.
It may be used for emergency indoor heating when
connected to a disposable 1 lb. propane cylinder and
for indoor use in commercial enclosures, having means
for providing combustion air and ventilation, such as
construction trailers or temporary work enclosures.
When the heater is cold or at room temperature, it
will take a few minutes for the burner(s) tile to turn
bright orange. This is normal and the heater is working
properly. If burner(s) tile is visibly flaming, turn heater
off and call a qualified service technician.
When the unit is lit, there should be about a quarter
inch border around the tile that will not turn bright
orange. This is normal.
• NOTE: THIS HEATER MAY BE OPERATED WITH (1) OR
LIGHTING / OPERATING INSTRUCTIONS
FOR USE WITH DISPOSABLE 1 LB.
PROPANE CYLINDERS:
WARNING:
propane connections for damage, dirt, and debris before
attaching propane cylinder. Do not use if head of cylinder is
damaged, punctured or deteriorated.
ALWAYS ATTACH OR DETACH CYLINDER OUTDOORS AWAY
FROM FLAMES, OTHER IGNITION SOURCES, AND ONLY WHEN
Figure A
HEATER IS COOL TO TOUCH. NEVER SMOKE WHEN ATTACHING
OR REMOVING PROPANE CYLINDER OR MAKING REMOTE
CONNECTIONS!
3
Mr. Heater | Big Buddy
Operating Instructions and Owner's Manual
When operating the heater at altitudes over 7,000
FT. above sea level, the unit may not burn as bright
as in lower altitudes. This is normal. At higher
altitudes, the heater may shut-off. If this happens,
provide fresh air, wait 5 minutes and re-light. Due to
local atmospheric conditions heater may not re-light.
Operating time will vary based on the temperature
of the surroundings and if running the heater on
low, medium, or high setting. Rough guidelines are
as follows: Single 1lb cylinder (1.5 to 6hrs); 2 x 1lb
cylinders (3 to 12 hrs); 20lb cylinder (24 to 108hrs); 2 x
20lb cylinders (48 to 216hrs). Heater may be operated
from quick disconnect, one or both regulated inlets.
Due to the properties of LP gas, run times can be
significantly reduced when operating continuously
at temperatures below 20ºF. Use of a 20 lb. tank is
recommended in these conditions.
When moving heater when lit or bumping heater setting
it down, tip over switch may shut off heater. If this
happens, re-light.
(2) DISPOSABLE 1 LB. PROPANE CYLINDERS OR WITH A
REMOTE REFILLABLE CYLINDER(S) MAX. 20 LBS USING
(1) OR (2) F273701, F273702 OR F272702 HOSE ASSEMBLIES
WITH FUEL FILTERS (F273699) (Fig. A) ON EACH HOSE
ASSEMBLY. HOSE NO. F273704 BUDDY SERIES HOSE,
FUEL FILTER NOT REQUIRED. IT MAY ALSO BE OPERATED
WITH (1) F271802 HOSE ASSEMBLY CONNECTED TO A
REGULATED (11" W.C.) PROPANE SOURCE OR (1) F271803
HOSE ASSEMBLY WITH 11" REGULATOR WITH ACME NUT.
Always inspect propane cylinder and heater
Use only LP-gas cylinders marked in accordance with the
U.S. Dept. of Transportation (DOT).
Use only 16.4 oz. (1 lb.) disposable cylinders that mate
with No. 600 valve connection.
Heater and attached cylinder(s) must be in an upright
position during operation.
Make sure five-position Control Knob is in "OFF"
position; see Figure 1.
Screw 1 lb. disposable LP-gas supply cylinder(s) clockwise
(from bottom) into portable heater until hand-tight.
DO NOT use thread sealant on this connection.
Check cylinder(s) connection for leaks with soapy water
at the threaded connection under the domed plastic
cover where the cylinder screws into the regulator. SEE
WARNING! ON PLASTIC COVER DOORS.