STEPS TO FOLLOW TO REALISE A CUTTING
1 Lif t slightly t he b lades saf eguard to save height o f t he f lange and then dr ag it completely l eftwards F ig.6
before you can lift it totally.
2 R esting the bars upon the rol ler so t hat you can e asily move t he ba r forward as per the pr edetermined
measurement. Place the bar in the thro at between th e tw o blad es. Lo wer back the blades saf eguard and pu s h it
rightward to free the pedal (the mechanism that operates the cutting).
Note: CEL models are equipped with a safety system that when the blades safeguard is lifted, the blades would not
be able to cut the material.
3 Once the safeguard has be en released, w e can effe ctuate a cutting, either by pres sing the peda l or pullin g
the grip.
Never try to make a cut while the safeguard is lifted as the material to cut can leave the cutting throat and
cause damage.
5. SOLUTIONS TO MOST FREQUENT ANOMALIES
ANOMALY
Motor does not start
Motor starts very slowly and takes too
long to reach its revolutions
Cutting power is too low
Premature wearing of the belts
6. TECHNICAL CHARACTERISTICS
DETAILS
MOTOR POWER Kw.
MOTOR TENSSION
MOTOR R.P.M.
NET WEIGHT Kg.
DIMENSIONS L x A x H mm.
CUT PER MINUTE
OIL CAPACITY L
AUTEK MAQUINARIA 5392 7077
POSSIBLE CAUSE
Fault of the electrical power supply
activation of th e thermal protection of
the single-phase switch
Switch damaged
Condenser damaged.
(Single-phase motors)
Belt loose or blunt
Blades blunt
Power drop down of the motor
The belts slide over the pulleys
CEL-30 TRIF.
CEL-30 MONF.
1,5
230/400V~
230V~
50-60Hz
50-60Hz
3000
247
831x544x728
831x544x728
105
1
AUTEK MAQUINARIA 5392 7077
Check the pow er supp ly in th e switch
board. Check the position of t he circuit
breaker and the residual cur rent device
in the switch board.
Make sure the extension cable is in good
state and its fitting in the two extremes is
correct.
Wait un til the mo tor has co oled down
and re-activate the thermal protection
Replace it
Replace it
Tighten the belt or replace it
Change the cu tting face of the blad e
or replace it
Let th e technical service ch eck th e
motor.
Tighten the belts
CEL-35 TRIF.
1,5
2,2
230/400V~
50-60Hz
3000
3000
247
391,6
933x631x689
105
100
1
1.3
SOLUTION
CEL-45 TRIF.
3
230/400V~
50-60Hz
3000
666
1147x640x915
60
9