6.1 CUTTING CHARACTERISTICS TABLE
7. ELECTRICAL SCHEME
CEL-30, 35, 45.
7.1 ELECTRICAL CONNECTION
The extension cable used to feed the machine needs to have a minimum section of 4x2.5 mm
meters long. For a superior distance 4x4 mm
normalised aerial of 3P+T or 3P+N+T compatible with the machine switch and in the other end, one normalised aerial
pin of 3P+T ó 3P+N+T compatible with switchboard exit.
Machines with electrical motor should always be connected to a normalised switchboard that disposes of a
magneto-thermal switch and a differential in accordance with the characteristics of the motor:
3Kw /4 CV, three phase at 400V, 15A magneto-thermal and 15A/30mA differential.
4Kw / 5.5 CV, three phase at 400V, 10A magneto-thermal and 10A/30mA differential.
The machine electrical tension is visible on the voltage indication next to the top of engine terminals and on the
machine characteristics plate.
WARNING: Do not plug the machine to the electricity if you are not sure of the available electrical tension.
If the tension is not correct, the engine will undergo irreparable harm or out of service.
WARNING: Never manipulate the power cables or any electrical equipment of the machine, if you have not
totally unplugged the machine from the electricity.
Once you have brought the rotation direction of the engine back, the machine is ready to operate.
IMPORTANT: It is appropriate to change the position of the bridge plates in the engine terminals. It is also important
to change the adhesive labels indicating the voltage, to reflect the change made.