Repairs; Troubleshooting Guide - Powermate PWFC132600 Manual De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING GUIDE

• SAVE ALL INSTRUCTIONS
Problem
Engine will not start (see Engine
Manual for further engine trouble-
shooting)
No or low pressure (initial use)
Will not draw chemicals
No or low pressure (after period of
normal use)
Water leaking at gun/spray wand
connection
Water leaking at pump
Pump Pulsates
AWSC= Authorized Warranty Service Center

REPAIRS

• SAVE ALL INSTRUCTIONS
To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by an Authorized Warranty Service
Center. Always use identical replacement parts. For the location of the nearest Authorized Warranty Service Center call 1-888-895-4549 or visit
our website www.powermate.com.
Copyright © 2011 MAT Industries, LLC
Cause
1. No fuel
2. Pressure builds up after two pulls on the recoil starter
or after initial use.
3. Choke lever in the "No Choke" position.
4. Spark plug wire not attached.
5. Engine ON/OFF switch in OFF position.
6. Choke lever in the "Choke" position on a "hot" engine
or an engine that has been exposed to thermal heat for
a long period of time.
1. High pressure nozzle is not installed.
2. Low water supply.
3. Leak at high pressure hose fi tting.
4. Nozzle obstructed.
5. Water fi lter screen clogged.
6. Air in hose.
7. Choke lever in the "Choke" position.
8. High pressure hose is too long.
1. Low pressure soap nozzle not installed.
2. Chemical fi lter clogged.
3. Chemical screen not in cleaning solution.
4. Chemical too thick.
5. Pressure hose too long.
6. Chemical build up in chemical injector.
1. Worn seal or packing.
2. Worn or obstructed valves.
3. Worn unloader piston.
1. Worn or broken O-ring.
2. Loose hose connection.
1. Loose connections.
2. Piston packing worn.
3. Worn or broken O-rings.
4. Pump head or tubes damaged from freezing.
1. Nozzle obstructed.
Correction
1. Add fuel.
2. Squeeze gun trigger to relieve pressure.
3. Move choke to the "Choke" position.
4. Attach spark plug wire.
5. Place engine ON/OFF switch in ON position.
6. Move choke to the "No Choke" position.
1. See How to Use Spray Wand instructions in the Operation
Section.
2. Water supply must be at least 5 GPM @ 20 PSI.
3. Repair leak. Apply sealant tape if necessary.
4. See Nozzle Cleaning instructions in the Maintenance sec-
tion.
5. Remove and clean fi lter.
6. Turn off the engine, then the water source. Disconnect
the water source from the pump inlet and turn the water
source on to remove all air from hose. When there is a
steady stream of water present, turn water source off. Re-
connect water source to pump inlet and turn on water source.
Squeeze trigger to remove remaining water.
7. Move choke to the "No Choke" position.
8. Use high pressure hose under 100 feet.
1. See How to Use Spray Wand paragraph in the Operation
Section.
2. Clean fi lter.
3. Make sure end of chemical hose is fully submerged into
cleaning solution.
4. Dilute chemical. Chemical should be in the same consis-
tency as water.
5. Lengthen water supply hose instead of high pressure
hose.
6. Have parts cleaned or replaced by AWSC.
1. Have replaced by AWSC.
2. Have replaced by AWSC.
3. Have replaced by AWSC.
1. Check and replace.
2. Tighten.
1. Tighten.
2. Have replaced by AWSC.
3. Have replaced by AWSC.
4. Have replaced by AWSC.
1. See Nozzle Cleaning paragraph in the Maintenance sec-
tion for the correct procedure.
12 - ENG
200-2835
Tabla de contenido
loading

Tabla de contenido