Flammable material hazard.
CAUTION: It is strictly forbidden to re-
move the safety signs on the units.
REFRIGERANT CIRCUIT
The refrigerant gas used in these units is
R-454c. The refrigerant circuit is built in com-
pliance with current standards.
Flammable material hazard.
This unit is hermetically sealed and contains
fluorinated gas R-454c GWP =146.
2. CONSTRUCTION
► Dehumidifier FIG. 1
1. Handle
2. Control panel
3. Wheel
4. Water tank
5. Water tank panel
6. Filter grill
7. Hour counter
► Control panel FIG. 2
1. humidity display
2. operate indicator
3. defrost indicator
4. memory indicator
5. tank full indicator
6. memory
7. humidity up
8. humidity down
9. on/off button
3.
OPERATION
KEYS:
► ON/OFF: Press ON/OFF, the unit runs in a
circulation "ON-OFF-ON".
► Humidity up and down: Press "humidity up
and down" for once, the set humidity will in-
crease or decrease by 1%. Press the key for
1.5 seconds and the set value will increase or
decrease by 1%. Press continuously with the
speed 5 points per second.
► Memory Key: Press the memory key and the
memory indicator will light on to start the func-
tion of memory when the power cuts off. Press
INSTRUCTION OF
the memory key again; the memory indicator
dies to shut off the function of memory when the
power is cut off.
START ON:
► Plug on the unit gives off "di".
► Press "ON/OFF", the running indicator lights
on, and the humidity display window lights on
to display the previously set humidity. The initial
humidity setting is 60% and 3 seconds later the
humidity display window lights on to display cur-
rent humidity.
► Press humidity up or down key to adjust the
humidity needed. If the set humidity is 3% less
than current humidity, the unit runs; if the set hu-
midity is 3% more than current humidity, the unit
stops running.
► When set humidity is less than 30%, the unit
dehumidifies continuously, and the humidity dis-
play window reads "CO".
SHUT OFF:
► Press "ON/OFF" when the unit is running, the
unit stops running and all indicators die.
NOTICES:
► When the set humidity is higher than current
humidity, the unit will not run.
► When the tank is full, the tank full indicator
lights on, meanwhile, the compressor and the
fan motor shut off automatically, and the buzzer
gives off "DD" sound. Unless the tank is emp-
tied, the buzzer gives the "DD" sound every 5
minutes. Only after emptying the tank the unit
will start running again.
► When dehumidifying, the fan motor and com-
pressor must be running at least for 3 minutes,
once the compressor starts on. It is strongly for-
bidden to restart the compressor again within 3
minutes after the shut off.
► When operating in low temperature, the unit
judges the system temperature automatically to
defrost. When defrosting, the defrosting indica-
tor lights on, the compressor runs but fan motor
shuts off automatically.
► When you press the memory key, the control-
ler will record current humidity even if the power
is off. The unit will run under previous mode af-
ter power supplied again.
► The humidity display window shows humidity
from 30% to 90%.
► Keep the unit unplugged if not used for a long
time.