Sime Brava Slim 40 BF Manual De Instalación Y Mantenimiento página 91

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
Type
No.
Description
PAR
24
External relay 2 function
PAR
25
Auxiliary TA function
PAR
26
Zone Valve / Pump Relaunch Delay
PAR
28
DHW activation delay with solar power
Anti-legionella Function (Only hot water tank)
PAR
29
-- = Disabled
PAR
30
Maximum domestic hot water temperature
PAR
35
Digital / analogue Pressure switch
PAR
40
Modulating Pump Speed
PAR
41
∆T Modulating pump delivery/Return
PAR
47
System pump forcing (only in winter mode)
PAR
48
INST Parameter set to default
In the event of a fault/malfunction the message "ALL" will
appear on the display with the alarm number eg. "ALL 04"
(Domestic Hot Water Sensor Fault).
Before repairing the fault:
– disconnect the appliance from the mains power by setting the
main switch to "OFF"
OFF
– as a precautionary measure, close the gas isolation valve.
Range
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
0 = according to TA
1 = TA Antifreeze
2= domestic hot water disabled
0 .. 99
0 .. 30
50 .. 80
35 .. 67
0 = water pressure switch
1 = water pressure transducer
2 = water pressure transducer (only
pressure displayed)
-- = No modulation
AU = Automatic 30 .. 100
10 .. 40
0 = Disabled
1 = Enabled
RESET
0 .. 1
Repair the fault and start-up the boiler again.
after having repaired the fault, when the alarm number
NOTE:
appears on the display together with the message
(see figure), press the button
to start the appliance up again.
Fig. 32
U/M
Step
Default
-
-
0
-
1
0
Min
1
1
Min
1
0
-
1
--
°C
1
60
-
1
1
%
10
AU
°C
1
20
-
1
0
-
-
0
d
y
for approximately 3 seconds
91