Enlaces rápidos

Franklin Electric Co., Inc.
Oklahoma City, OK 73127
www.lg-outdoor.com
INTRODUCTION
EN
This instruction sheet provides you with the information required to safely own and
operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship
and material, and has been engineered to give you long and reliable service.
Little Giant pumps are carefully tested, inspected, and packaged to ensure safe
delivery and operation. Please examine your pump carefully to ensure that no
damage occurred during shipment. If damage has occurred, please contact the
place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP . KNOW
THE PUMP'S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS
COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
Ensure that the pump is disconnected from the power source before attempting
to service or remove any component.
This pump is not submersible.
Do not handle a pump or pump motor with wet hands or when standing on a wet
or damp surface, or in water.
This pump is supplied with a grounding conductor and/or grounding-type
attachment plug. To reduce the risk of electric shock, ensure that it is connected to
a properly-grounded, grounding-type receptacle.
In any installation where property damage and/or personal injury might result
from an inoperative or leaking pump due to power outages, discharge line
blockage, or any other reason, use a backup system and/or alarm.
Support the pump and its piping during assembly and after installation. Failure
to do so may cause damage to the pump and/or piping.
ELECTRICAL CONNECTIONS
This pump must be installed by qualified personnel, following all local electrical
and safety codes, as well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).
Check the pump label for proper voltage required. Do not connect the pump to
any voltage other than that shown.
If your pump is equipped with a 3-prong electrical plug, the third prong grounds
the pump to prevent possible electrical shock hazard. Do not remove the third
prong from the plug. A separate branch circuit is recommended. Do not use an
extension cord when connecting the pump to its power source.
Refer to Table 1 to determine proper voltage. The pumps are pre-configured at
the factory for 115V operation. If 230V operation is required, refer to the label on
the motor for directions on wiring the pump. BE SURE OF PROPER ROTATION.
IMPROPER ROTATION WILL SEVERELY DAMAGE THE PUMP AND VOID THE
WARRANTY.
MATERIALS OF CONSTRUCTION
Volute ........................................................................... Glass-filled polypropylene
Impeller ....................................................................................Glass-filled Noryl®
Drain plug..................................................................... Glass-filled polypropylene
Bracket ......................................................................... Glass-filled polypropylene
Seal (impeller) ..........................................................................Ceramic & Buna-N
Seal (shaft) ......................................................................................... Carbon face
O-rings ....................................................................................................... Buna-N
Hardware ......................................................................................... Stainless steel
LEAF BASKET (OPTIONAL)
Little Giant offers an optional leaf basket for use with the OPWG pumps. The
leaf basket is important for providing filtration to the water in the pond and
keeping large debris from going into the pump. The leaf basket is a necessity for
installations where the pump is located above the water source (Figure 3). The
leaf basket is ready for assembly with any of the OPWG series pumps.
OPWG SERIES OUT-OF-POND
WATER GARDEN PUMP
POMPE NON SUBMERSIBLE
POUR BASSIN DE JARDIN
SÉRIE OPWG
BOMBA FUERA DE ESTANQUE
PARA JARDIN ACUÁTICO
WARNING
INSTALLATION
PLEASE READ ALL INSTRUCTIONS BEFORE OPERATING THE OUT-OF-POND
WATER GARDEN PUMP . The Out-Of-Pond Water Garden Pump is not self-priming;
therefore, if the water source is below the pump, a foot valve must be installed and
the pump should be primed prior to startup. Do not restrict the intake of the pump.
Do not pump water with temperatures above 95°F. Pipe used for connecting to the
intake side of the pump should not be of smaller inside diameter than that of the
intake thread designation. THIS PUMP IS NOT SUBMERSIBLE.
NOTE: IT IS IMPORTANT TO LOCATE THE PUMP AS CLOSE AS POSSIBLE TO
THE WATER SOURCE. THIS WILL KEEP THE INTAKE PIPING AT A MINIMUM
LENGTH. USING LONGER SECTIONS OF PIPE AND ADDITIONAL ELBOWS
WILL ADD ADDITIONAL FRICTION LOSSES AND COULD AFFECT THE
PRIMING CAPABILITY AND PERFORMANCE OF THE PUMP .
1. Determine a suitable, permanent location near the water source (pond,
skimmer, filter, etc.) to mount the pump. There are 3 installation options
available for the Out-Of-Pond Water Garden Pump (Figures 2-4).
2. Mount the motor base on a hard, level foundation for all mounting
installations. DO NOT install pump below ground level or in a low-lying
area where flooding could occur. Make sure that the mounting surface has
adequate drainage so that water will not collect around the pump and motor
housing. If possible, when installing the pump, place a protective barrier
over the pump to protect the motor from heavy rainfall, which could damage
the motor and possibly cause electric shock. This barrier should also allow
clearance around pump motor for air circulation.
3. Determine what type of water feature will be used with the pump and
determine its location in reference to the pump. Perform a preliminary
layout of the piping and adapters to determine the proper length of the
pipe sections. Minimize the number of elbows used in the intake and
discharge lines. This will reduce the friction losses and maximize the pump
performance. The intake line coming from the water source should be kept
at a minimum length. Once the layout is determined for the water garden
pond, begin making the permanent connections for the fittings.
4. Use only plastic PVC-type fittings on both the pump intake and discharge
(Table 1). All piping should be 2" PVC or flexible type piping. All threaded
connections should be sealed with Teflon tape and the slip-fit piping
connections should be sealed with PVC cement. Use compatible cement
when connecting PVC piping to PVC adapters or PVC adapters to flexible
piping. All piping should be supported and arranged for ease of alignment
to the intake and discharge ports on the pump (or with the optional leaf
basket). Forcing alignment of the piping to the intake and discharge ports
on the pump volute can cause damage to the volute/leaf basket.
5. The Out-Of-Pond Water Garden Pumps are not self-priming. DO NOT RUN
THE PUMP DRY. A flooded intake is recommended for optimum performance
because it eliminates the risk of running the pump dry or losing prime. THE
LEAF BASKET AND ALL HARD PIPING DOWN TO THE FOOT/CHECK
VALVE MUST BE FILLED WITH WATER BEFORE RUNNING THE PUMP .
6. For in-line use, install the pump so that the pump head (volute) is flooded
when the pump is started. That is, the inlet of the pump must be below the
level of the surface of the liquid being pumped (Figure 1).
When installing the pump above water level, use a foot valve or check
valve on the piping leading to the intake of the pump for pumping from the
water source (pond, skimmer, filter, etc.) The foot/check valve will maintain
the water in the intake line when the pump is not in operation. Figures 2-4
outline some typical installations for the Out-of-Pond Water Garden Pumps.
(See Table 1 for pump intake and discharge sizes.)
7. For all installations, an adjustable ball/gate valve should be used above the
discharge of the pump. The ball/gate valve helps control the water flow for
the water feature being used. When the pump is being serviced, be sure to
close off the ball/gate valve to prevent back-flowing of the water from the
waterfall/water feature.
8. When installing the pump below water level, an additional ball/gate valve
should be installed in the line ahead of the intake or leaf basket so that water
flow from the water source can be shut-off for pump maintenance and/or
cleaning the leaf basket screen. DO NOT USE THIS VALVE TO RESTRICT
THE PUMP INTAKE.
FIGURE 1
WARNING
1
Tabla de contenido
loading

Resumen de contenidos para Little Giant OPWG-29

  • Página 1 Hardware ..................Stainless steel LEAF BASKET (OPTIONAL) Little Giant offers an optional leaf basket for use with the OPWG pumps. The leaf basket is important for providing filtration to the water in the pond and keeping large debris from going into the pump. The leaf basket is a necessity for installations where the pump is located above the water source (Figure 3).
  • Página 2: Maintenance/Repair Instructions

    Remove small end cap on other end of motor and use a standard Leaf basket screwdriver on the motor shaft to keep the shaft from rotating. The OPWG-29 and OPWG-46 pumps are equipped with a metal washer Standard 2” union To waterfall behind the impeller.
  • Página 3: Connexions Électriques

    PANIER À FEUILLES (EN OPTION) (no service required). The shaft seal requires no lubrication after assembly. Little Giant offre en option un panier à feuilles utilisable avec les pompes OPWG. FREEZING TEMPERATURES: Drain the pump of water before servicing or if Le panier à...
  • Página 4: Instalacion

    LA BOMBA FUERA DE ESTANQUE PARA JARDÍN ACUÁTICO. La bomba fuera El producto Little Giant que ha adquirido se fabrica utilizando mano de obra y de estanque para jardín acuático no es autocebante; por lo tanto, si la fuente materiales de la más alta calidad y ha sido diseñado para prestarle un servicio...
  • Página 5 4. Las bombas OPWG-29 y OPWG-46 están equipadas con una rondana metálica que esta atrás del impulsor. Si requiere cambiar la rondana, compare el espesor de la rondana que esta en le bomba con las dos nuevas rondanas que se surten junto con el impulsor nuevo y usar la rondana del mismo espesor.
  • Página 6 TROUBLESHOOTING PROBLEM • PROBLÈME • PROBABLE CAUSES • CAUSES PROBABLES • CAUSAS CORRECTIVE ACTION • MESURE CORRECTIVE• ACCIÓN CORRECTIVA PROBLEMA PROBABLES Motor will not rotate. • Le Blown fuse or breaker. •Le fusible est grillé ou le disjoncteur Check main power box for blown fuse or tripped circuit breaker, etc. • Vérifier le panneau principal de moteur ne tourne pas.
  • Página 7: Replacement Parts

    566021 566023 566024 • • ÍTEM NO. PIEZA NO. DESCRIPTION DESCRIPTION DESCRIPCIÓN OPWG-29 OPWG-46 OPWG-71 OPWG-97 915500 • • Bolt, carriage, 10-24 x 2-3/4” Boulon, carrosserie, 10-24 x 2 3/4 po Perno de cabeza de hongo y cuello cuadrado de 10-24 x 2-3/4 pulg 915501 •...
  • Página 8: Garantie Limitée

    4. This warranty policy does not cover any labor or shipping charges. The SHALL ALSO APPLY TO ALL DAMAGES RESULTING FROM CONDITIONS Company shall not be liable for any costs or charges attributable to any product SET FORTH IN SECTION III ABOVE AND (1) DEFECTS IN PRODUCT testing, maintenance, installation, repair or removal, or for any tools, supplies, PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT or equipment needed to install, repair, or remove any product.
  • Página 9: Garantia Limitada

    utilisation au-delà des maximums recommandés, comme énoncés dans les stipulation de cette garantie est interdite par ces lois, elle sera nulle et sans effet, instructions du produit. mais le reste de la présente garantie demeurera en vigueur. AVIS DE NON-RESPONSABILITE: Les déclarations orales concernant le produit 4.
  • Página 10: Descargo De Responsabilidad

    6. Los productos dañados por el desgaste normal, mantenimiento normal y las piezas utilizadas en conexión con dicho servicio o cualquier otra condición más allá del LA COMPAÑÍA NO SERÁ RESPONSABLE POR LOS DAÑOS ACCIDENTALES, control de la Compañía. CONSECUENTES O ESPECIALES TALES COMO, PERO NO LIMITADOS A: 7.
  • Página 12 Pour l’aide technique, entrez s’il vous plaît en contact ..1.888.956.0000 Para la ayuda técnica, por favor póngase en contacto ..1.888.956.0000 www.lg-outdoor.com [email protected] Form 998518 - 05/2013 Rev 001 © 2013 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Este manual también es adecuado para:

Opwg-46Opwg-71Opwg-97566020566021566023 ... Mostrar todo

Tabla de contenido