Cooper Lighting WIS Instrucciones De Instalación página 4

Idiomas disponibles

Idiomas disponibles

Installation Instructions - WIS - Lumiere Instructions
SIGNS
1.
Unpack and ensure all included parts are present.
2.
Unscrew 4x mounting hardware from driver mounting
plate, separate the Luminaire Disconnect to separate
driver mounting plate from fixture assembly.
3.
Connect building AC supply wires from junction box to
input wire side of LED driver with push nuts (included).
Connect ground wire to junction box. Ensure excess
ground wire can extend out of junction box.
Junction boxes must be min size of 2-1/8" deep
N
ote:
and 4" square. Recommended Junction boxes are
Crouse-Hinds part numbers TP403, TP432, TP434,
TP438, TP395, or equivalent.
Driver Mounting Plate
Driver
RD
BK
GN
Push Nuts
Ground Wire
Mount Plate and Gasket
Fixture Assembly
Figure 6.
4.
Separate and route Luminaire Disconnect and ground
wire out of center hole in driver mounting plate, Attach
driver mounting plate to existing junction box with
proper hardware (not included).
5.
Re-connect ground wire and Luminaire Disconnect
to fixture assembly. Attach mount plate and gasket
to driver mounting plate with 4x mounting hardware.
Ensure adequate gasket compression to provide proper
seal from the environment.
4
COOPER LIGHTING SOLUTIONS IL514001EN
Luminaire Disconnect
Mounting Hardware
Knuckle
Installation instructions
Driver Mounting Plate
Luminaire Disconnect
RD
BK
GN
Ground Wire
Mount Plate and Gasket
Figure 7.
6.
Using a 3/32" Allen Wrench, slightly loosen the set
screw at knuckle base for rotational adjustment. Using
a 9/64" Allen Wrench, slightly loosen the screw at
the knuckle joint for angle adjustment. Once properly
positioned, ensure both screws are secured.
Set Screw
Mount Plate and Gasket
Fixture Assembly
Figure 8.
Mounting Hardware
Knuckle
Fixture Assembly
Knuckle Joint Screw