CEILING INSTALLATION LOUDSPEAKER
OPTION 3: LOW IMPEDANCE SETUP
For added flexibility, the TNi-C Range provides a Low impedance setting for use with a conventional amplifier.
TNi-C4
TNi-C6 and TNi-C8
7 0 V
8 Ω
100V
AMPLIFIER
AUDIO OUTPUTS
100V
COMMON
For a Low Impedance setup, ensure the + speaker cable IS NOT connected to the 70V/100V output. Doing so could result in
damage to the Ceiling Speaker.
Depending on the amplifier used, it may be possible to use more than one loudspeaker in this mode.
LOW IMPEDANCE - PARALLEL CONNECTION - The amplifier will see a combined speaker impedance of 4Ω.
AMPLIFIER
AUDIO OUTPUTS
100V
COMMON
LOW IMPEDANCE - SERIES CONNECTION - The amplifier will see a combined speaker impedance of 16Ω.
AMPLIFIER
AUDIO OUTPUTS
100V
16Ω
COMMON