CEILING INSTALLATION LOUDSPEAKER
Power Modes: Depending on the required output level, and the type of amplifier used to power the system, connec ons and
se ngs will change. These are summarized below:
OPTION 1: 70V LINE SYSTEM
Audio connection and audio tap setup.
TNi-C4
TNi-C6 and TNi-C8
7 0 V
7 0 V
8 Ω
100V
100V
AMPLIFIER
AUDIO OUTPUTS
70V
COMMON
OPTION 2: 100V LINE SYSTEM
Audio connection and audio tap setup.
7 0 V
7 0 V
8 Ω
100V
100V
TNi-C4
TNi-C6 and TNi-C8
AMPLIFIER
AUDIO OUTPUTS
100V
COMMON
70V/100V line systems have the added advantage of allowing many speakers to be used in the setup using parallel connections.
Ensure the cable used is capable of delivering the working current and the amplifier has sufficient drive capacity to support
the number of speakers in the system.
AMPLIFIER
AUDIO OUTPUTS
70V/100V
COMMON
© 2021 HH Electronics Ltd
8 Ω
+ _
8 Ω
+ _
Designed and Engineered in the UK by HH Electronics LTD.
TNi-C4
TNi-C6 and TNi-C8
3W
5W
7 0 V
8 Ω
100V
7.5W
10W
7 0 V
8 Ω
100V
15W
20W
7 0 V
8 Ω
100V
TNi-C4
TNi-C6 and TNi-C8
6W
7 0 V
8 Ω
100V
15W
7 0 V
8 Ω
100V
30W
7 0 V
8 Ω
100V
+
+
_
_
iNSTALL
7 0 V
8 Ω
100V
7 0 V
8 Ω
100V
7 0 V
8 Ω
100V
10W
7 0 V
8 Ω
100V
20W
7 0 V
8 Ω
100V
40W
7 0 V
8 Ω
100V
+
+
_
_
+
_
+
_
+
_