10. Connect the supply side line voltage wire to the
fixture side line voltage terminal connector (black
wires).
11. Connect the supply side neutral wire to the fixture
side neutral wire terminal connector (white wires).
12. Close the cover and tighten the three screws to
insure the fixture will maintain it's water tight seal.
13. Replace pole top cap after completion of fixture
installation and wiring.
Note: For installation to round poles follow the same
instructions as the square pole installation with
the additional round pole adaptor inserted
between the pole and the arm (FIG. 1).
FIG. 1
Grommet (For Service Leads)
Threaded Rod
Angled Edge
Arm
Nut Plate
Access Door
Round Pole Adapter (Optional)
Tools Required
#2 Phillips screw driver, ratchet and a 3/4" shallow socket.
Wall Mount (FIG. 2)
1.
Loosen (3) screws located in the access door of the
fixture and open the door.
2.
Install the 1st mounting bolt through the top side
hole at the back of the fixture. Slide a lock washer
and nut onto the bolt inside the housing but do not
tighten.
3.
Install the 2nd mounting bolt through the bottom
side hole at the back of the fixture. Slide a lock
washer and nut onto the bolt inside the housing
but do not tighten.
4.
Slide the included arm over the bolts as shown in
FIG. 2. Make sure the angled portion of the arm
matches the angle at the back of the fixture so that
Mounting Hardware Detail
LED Area/Site Luminaire Installation Instructions IMI-811 ADH140439 www.eaton.com
Galleon
TM
Galleon
LED Area/Site Luminaire Installation Instructions
TM
the assembly will be level upon completion.
The long side should be at the top of the fixture.
5.
Place the decorative wall plate over the arm bolts
and secure to the back side of the arm using the
supplied lockwasher and nuts.
6.
Tighten the nuts on the back of the decorative wall
plate to 480 ft-lbs. Set the fixture assembly aside.
7.
Pull the supply wires out of junction box (not
included) and through the large hole in the center
of the attachment plate.
8.
Secure attachment plate to the wall using four bolts
(not included).
9.
Pull the supply wires into the center hole of the
decorative wall plate and into the fixture assembly
(passing through the silicone rubber wire grommet)
from step 6.
10. Hang the decorative wall plate onto the attachment
plate and tighten the screw located at the bottom of
the decorative wall plate to 15 in-lbs.
11. Inside the fixture, connect supply wires to
appropriate fixture leads:
a. Supply side ground wire to green fixture lead.
b. Supply side neutral wire to white fixture lead.
c. Supply side line voltage wire to black fixture lead.
12. Close the cover and tighten the three screws to
insure the fixture will maintain its water tight seal.
FIG. 2
Threaded Rod
Mounting Arm
(Angled edge torward xture)
Decorative Wall
Plate
Wall Gasket
Access Door
Attachment Plate
(Hardware by Others
Mounting Hardware Detail
(Washer/Lockwashers and Nuts)