10.2006
Setpoint and command source
Terminal strip and
analog input
Differential input
+/- 10 V
AI+
-X101/9
AI-
-X101/10
Control type:
Speed
control
Ref-
Norm.
speed
P353
Disp Speed Conn
r041.1
(= speed
setpoint)
Time P462.1
Analog output
+/- 10 V
AA
-X101/11
A
D
-X101/12
Type of encoder:
Resolver
Data of resolver to be connected:
- 2-pole
Data of pulse encoder simulation:
- 1024 pulses/revolution
Siemens AG
6SE7087-8JK50
SIMOVERT MASTERDRIVES
-X101/1
P24
-X101/2
M24
1 = Operation
-X101/3
0 = Fault
-X101/4
0 = Alarm
-X101/5
1 = Inverter relesae
-X101/6
1-Edge = Acknowledge
-X101/7
-X101/8
1 = ON 0 = OFF1
-10 V ... + 10V
corresponds to
A
-100 % ... +100 %
D
r003 Output Volts
r004 Output Amps
r006 DC Bus Volts
n-Reg. Gain1
n(max, FWD speed)
P452.1
n(max, REV speed)
P453.1
Accel
Decel
Time P464.1
AnaOut Scale
AnaOut Offset
P643.1
P644.1
y
x
y[V]=
P643.1
100 %
Operating Instructions
AnaIn Scale
P630
AnaIn Offset
P631
n-Reg. Time
P235.1
P240.1
FSetp
Torq(Lim1)
P263.1
FSetp
Torq (Lim2)
P264.1
AnaOut Smooth
P642.1
x
SBR1/2
-X410/90
Track A+
-X410/91
Track A-
-X410/92
Track B+
-X410/93
Track B-
-X410/94
Zero pulse +
-X410/95
Zero pulse -
Parameterization
AnaIn Smooth
P634
Current
control
Motor
encoder
Disp Speed Conn
r041.2
(=speed actual value )
sin +
-X414/3
sin -
-X414/4
cos+
-X414/6
cos-
-X414/7
Excitation
-X414/9
M
-X414/11
Excitationg
Shield connection
Motor
3~
6
8-31