Installation; Mounting The Unit - Stiebel Eltron DHC 3-1 Classic Operación E Instalación

Calentador de agua instantáneos sin tanque
Ocultar thumbs Ver también para DHC 3-1 Classic:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION

MOUNTING THE UNIT

INSTALLATION
5.
Mounting the unit
7
1
1 Electrical junction box
2 1/2˝ water supply line for faucet installation
3 Shut-off valve
4 Cold water supply
5 Sink
6 Cold valve (right)
7 Hot valve (left)
DANGER: Electrocution
The unit must be installed in a vertical position with the
water fittings pointing downward. Do not install unit
where it would routinely be splashed with water. Elec-
tric shock may result.
1. Install DHC Classic as close as possible to the hot water draw-
off point, for example, directly underneath the sink.
2. Install DHC Classic in a frost free area. If frost may occur, re-
move unit before freezing temperatures set in.
3. Leave a minimum of 5˝ of clearance on all sides for servicing.
4. Remove plastic cover by loosening the screw on the bottom.
Lift cover off from the bottom. When reinstalling, insert the top
of the cover into the rear housing first, then tilt the bottom into
place. Re-tighten the cover screw.
WWW.STIEBEL-ELTRON-USA.COM
5. Mount the unit securely to wall by putting two screws through
the mounting holes. Screws and plastic wall anchors for
mounting on drywall or wood are provided.
6
5
4
3
2
DHC CLASSIC |
5
Tabla de contenido
loading

Tabla de contenido