Electrical supply MUST match pump's name-
plate specification. Incorrect voltage can cause
fire or damage to the motor and voids warranty.
Motors without built-in protection MUST be
provided with contactors and thermal overloads
for single phase motors, or starters with heaters
for three phase motors. See motor nameplate.
Follow motor manufacturer's wiring diagram on the
motor nameplate or terminal cover carefully.
Use only copper wire to motor and ground. The ground
wire MUST be at least as large as the wire to the motor.
Wires should be color coded for ease of maintenance.
RECOMMENDED MINIMUM WIRE SIZE
Distance from Service Entrance to Motor
HP
50 Ft. (15 m) 100 Ft. (30 m) 150 Ft. (46 m) 200 Ft. (61 m)
115 V 230 V 115 V 230 V 115 V 230 V 115 V 230 V
¾
12
14
10
1
12
14
8
10
14
8
2
10
14
8
3
12
FAILURE TO PERMANENTLY
WARNING
GROUND THE PUMP, MOTOR AND
Hazardous
CONTROLS BEFORE CONNECT-
voltage
ING TO ELECTRICAL POWER CAN
CAUSE SHOCK, BURNS, OR DEATH.

Rotation

Rotation
NOTICE: INCORRECT ROTATION MAY CAUSE
DAMAGE TO THE PUMP AND VOIDS THE
WARRANTY.
Correct rotation is right hand, CLOCKWISE when
viewed from the motor end.

Operation

Operation
OPERATION WITHOUT PRIME, OR
WARNING
AGAINST A CLOSED DISCHARGE
VALVE, CAN GENERATE HOT WA-
TER OR STEAM CAUSING INJURY
OR PROPERTY DAMAGE.
NOTICE: DO NOT OPERATE PUMP
WITHOUT PRIME OR SEAL
Extreme heat can
DAMAGE WILL RESULT.
cause personal injury
or property damage
Prime pump by filling pump and piping through
opening in top of tee with clean water. See Figure 1.
Install pipe plug in top of tee using Teflon ™ tape or
equivalent.
NOTICE: IF PUMP IS DRAINED OR SHUT OFF
DURING PRIMING PERIOD, CASING
MUST BE REFILLED BEFORE
RESTARTING PUMP.
Start the pump and partially open discharge valve and
wait for system pressure to stabilize. If system pressure is
surging, or prolonged pressure drop is experienced, the
system may not be completely primed.
4
14
8
14
6
12
14
8
12
6
12
14
12
10
14
12
10
12
10
10
Maintenance – All Models
Maintenance – All Models
FAILURE TO DISCONNECT
WARNING
ELECTRICAL POWER BEFORE
ATTEMPTING ANY MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH.
No lubrication is required on pump.
For motor lubrication, refer to and
Hazardous voltage
follow manufacturer's instructions.
can shock, burn or
cause death.

SEASONAL SERVICE

To REMOVE pump from service, turn power off,
remove all drain plugs and drain all piping.
To RETURN pump to service, replace all drain plugs
using Teflon ™ tape or equivalent.
Reconnect suction line if removed, examine union and
repair if necessary.
Reprime and operate pump following all instructions
and warnings in the "OPERATION" section of manual.
Disassembly – RJSP
Disassembly – RJSP
FAILURE TO DISCONNECT
WARNING
ELECTRICAL POWER BEFORE
ATTEMPTING ANY MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH.
Hazardous voltage
can shock, burn or
cause death.
1. Remove foot bolt (10).
2. Remove casing bolts (12).
3. Remove back pull-out assembly from casing (2).
4. Remove guidevane seal ring (3) and diaphragm (4).
5. Remove guidevane screws (5) from adapter (11).
6. Remove motor end plug or cover.
7. Restrain motor shaft from rotation by utilization of
the screwdriver slot, or
motor shaft end.
8. Remove impeller (7), turning COUNTER-
CLOCKWISE.
9. Using two screwdrivers, pry off rotary section of
mechanical seal (8). Discard. See Figure 2.
10. Remove motor adapter bolts (13) and remove motor
adapter from motor.
11. Push stationary seat of mechanical seal out of
motor adapter. Discard seal seat.
Figure 2