Regeneration time
G
Press
.
Regeneration time flashes.
H
Adjust displayed time with
Default setting: 2:00am.
I
Press
to validate the selection and advance to the next parameter.
The following steps appears after regeneration time, do not modify them :
Days override (762, 764 controllers only)
Day of week regeneration (742 controller only)
Estimated system capacity
4.2.
History
To access the recorded information, press simultaneously
5 .
Operation
5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• for optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• do not use ice melt, block, or rock salts;
• the sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the life of
the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the system.
5.2.

Manual regeneration

Note:
The unit returns to normal operation if no buttons are pressed within 30 seconds.
Immediate regeneration
A
Press and hold
for 5 seconds.
Regeneration icon displayed.
Camshaft starts rotating to cycle C1.
Manual delayed regeneration
The regeneration will start on the scheduled date.
A
Press
.
Regeneration icon flashes.
6 .
Maintenance
Mandatory:
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper functioning of the
complete system, and be documented in the Maintenance record book.
Mandatory:
The maintenance and service operation must be done by qualified personnel only. Failure in respecting this may void
the warranty.
7 .
Troubleshooting
Please follow this procedure for any technical support:
A
Collect the required information for a technical assistance request.
Product identification (see 2.1. Serial label location, page 5 and Original settings, page 2);
Error number displayed on the controller;
B
Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
Ref. MKT-UG-021 / B - 09.10.2019
and
.
Days between regeneration (742 controller only)
Hardness (762 controller only)
Amount of salt used per regeneration
and
when the controller is in service mode.
Immediate double regeneration
B
When cycle C1 starts, press and hold
x2 icon displayed.
Note:
The second regeneration begins after current
regeneration completed.
Note:
To cancel: press
User Guide 255 / LOGIX 742-762-764
for 5 seconds.