General Specifications; Electrical Specifications; General Safety Information - World Dryer NOVA 2 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Description
NOVA 2 warm air hand dryer, powered by a dual blower, universal brush motor. This low profile, hand dryer is multi-voltage running
on 110 up to 240 Volt AC electrical supply. Operation is automatically controlled on/off, by an infrared sensor. This appliance is
intended for use in hand drying, contributing to hygienic and cost effective hand sanitation in commercial, office and medium
duty environments.

General Specifications

Models
Nozzle
0930
Dual Blower

Electrical Specifications

Models
Type
0930
Automatic
0930
Automatic
(*) This hand dryer is a multi-voltage appliance that will self adjust to the available supply from 110 up to 240 VAC.
(**) As measured, Root Mean Square (RMS)

General Safety Information

DANGER
• Always disconnect the power source before servicing or installing the hand dryer.
DANGER
• This hand dryer must be properly grounded (Earthed) for safe opera tion. An identified ground connection point is supplied on the
chassis of this hand dryer.
• Although not required by the National Electrical Code, we recommend GFCI protection in wet or damp locations or as required by
local code.
WARNING
• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed.
• Connect the hand dryer to the nearest suitable distribution panel.
• To limit a voltage drop, and insure efficient operation, use No. 12 wire or larger as required by local or National Electrical Code.
• Do not connect to a branch circuit with CB or fuse protection over 20 Amps. This is in compliance with The National Electrical Code.
• All automatic model hand dryers must have a dedicated 20 Amp circuit as required by Underwriters Labora tories, Inc. (UL).
• Route all field wiring away from any moving parts within the hand dryer.
CAUTION
• Follow the mounting recommendations in Table 1.
WARNING
Unpacking
1. Remove all packing material. Recycling is recommended.
2. Carefully remove the hand dryer from the shipping carton, using care not to drop the appliance.
3. Inspect carefully for any damage that may have occurred during transit. Check for any loose, missing or dam aged parts. If the hand
dryer is dam aged, promptly inform the dealer where you purchased it.
Drying Cycle
Automatic
Electrical Input *
110-120 VAC, 50/60 Hz
208-240 VAC, 50/60 Hz
Failure to disconnect the power source before installation can result in
serious injury or death from electric shock.
Failure to properly ground this unit could result in severe electrical shock
and/or death.
Risk of fire, personal injury or property damage are possible if local codes,
NEC codes or safety recommendations are not followed.
Improper mounting of this hand dryer could result in personal injury or
property damage.
Cancer and Reproductive Harm - www.p65warnings.ca.gov
Dimensions (WxDxH)
14" x 10" x 4.5"
Amperage **
Watts
15
1800
10
2400
2
Weight
11.3 lbs
cULus Listed E19860
Tabla de contenido
loading

Tabla de contenido