Install The Hardware - Axis Q60 Serie Guia De Instalacion

Ocultar thumbs Ver también para Q60 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99
AXIS Q60 Series
Specifications
Operating Conditions
The Axis product is intended for indoor use.
Product
AXIS Q6042
AXIS Q6044
AXIS Q6045
Power Consumption
NOTICE
NOTICE
NOTICE
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A. Axis
recommends using the supplied midspan.
Product
AXIS Q6042
AXIS Q6044
AXIS Q6045

Install the Hardware

NOTICE
NOTICE
NOTICE
• The AXIS product shall be connected using a shielded network cable (STP). All cables
connecting the product to the midspan shall be shielded (STP) and intended for their
specific use. Make sure that the midspan is properly grounded. For information about
regulatory requirements, see Regulatory Information, on page 2.
• Mount the product with the dome cover facing downward.
• Be careful not to scratch, damage or leave fingerprints on the dome cover because this
could decrease image quality. If possible, keep the protective plastic on the dome cover
until the installation is complete.
The Axis product can be installed with the cables routed through or along the wall or ceiling.
Read all the instructions before installing the product. Some installation steps would benefit from
being completed together because they require removal of the dome cover.
Classification
Temperature
IEC 60721-4-3
0 °C to 50 °C
Class 3K3, 3M3
(32 °F to 122 °F)
IEC 60529 IP52
PoE+
DC
21.1 W
24–34 V DC, max. 17.4 W
20.7 W
24–34 V DC, max. 17.9 W
21.8 W
24–34 V DC, max. 17.8 W
Humidity
10–85% RH (non-condensing)
AC
20–24 V AC, max. 24.7 VA
20–24 V AC, max. 25.9 VA
20–24 V AC, max. 26.0 VA
17
Tabla de contenido
loading

Este manual también es adecuado para:

Q6042 ptzQ6044 ptzQ6045 ptz

Tabla de contenido