AXIS Q60 Series
Function
GND
3.3 V DC Power 2
Configurable
(Input or
Output)
Digital output — For connecting external devices such as relays and LEDs.
Connected devices can be activated by the VAPIX® Application Programming
Interface, output buttons on the Live View page or by an Action Rule. The output
will show as active (shown under System Options > Port & Devices > Port
Status) if the alarm device is activated.
Digital input — An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass
break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under System Options > Port & Devices > Port Status).
Pin
Notes
1
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power
out.
3–6
Digital input — Connect to GND to
activate, or leave floating (unconnected)
to deactivate.
Digital output — Internal connection
to ground when activated, floating
(unconnected) when deactivated. If used
with an external relay, a diode must be
connected in parallel with the load, for
protection against voltage transients.
15
Specifications
Max load:
250 mA
0 to +40 V DC
Max load:
100 mA
Max voltage:
+40 V DC